background image

EDS  APPLICATION  NOTES

for various emergency oxygen back-up bypassing methods

The most common emergency bypassing method,
particularly for the EDS unit, is with the standard
issue F-2 oxygen mask kit.  The pilot simply
unplugs the 4 mm. service line from the equipment
to be bypassed and mates it to the union on the F-2
mask kit.  The flow indicator shows positive
oxygen flow for the duration of the cylinder's
capacity.  The on/off valve on the cylinder then
controls the flow of oxygen.

The second most common method uses a self-
sealing "Y" with the F-2 mask where the pilot
would simply connect the 4 mm. inlet tube of the F-
2 to the "Y" for emergency service.  This provides
the best and easiest to use back-up system for single
pilot applications.  In addition, an option for adding
a delivery device for a future passenger is provided.

The third most common emergency bypassing
method is with the A-4 flowmeter/regulator control
unit that couples the outlets of the EDS unit and the
A-4 unit together into one standard cannula.  This
allows the pilot to simply throw an on/off switch to
bypass the EDS unit, then having the ability to
adjust the flowmeter for the altitude to economize
on oxygen usage.

Because many pilots fly with passengers only part of
the time, the A-3 flowmeter/regulator and an
Oxymizer® cannula can be used for the passenger
instead of a second EDS unit.  This of course will
use more oxygen than each using an EDS, but will
prove acceptable as it is less expensive and can be
up-graded to an EDS in the future.

This figure (below) shows the most popular back-up
bypass arrangement for the dual EDS systems.  The
second set of "Y" split kit connecting the EDS units
and the F-2 mask kits are the self-sealing type.  The
auxiliary opening will stay sealed until the 4 mm.
inlet tubing of the F-2 mask kit is plugged in for
emergency service.

Oxymizer is a trade mark of Chad Theruputics, inc.

The EDS has proven to be a very reliable oxygen delivery

device used by many in various types of aviation and has

no means inside itself to provide a by pass of oxygen in

the event of a total failure.  Therefore, here are a few

oxygen bypassing methods implemented for that

comforting peace of mind.

Summary of Contents for EDS A-1

Page 1: ...erations up to 17 999 ft or a face mask for flight operations over 17 999 ft and up to 30 000 ft Both of these items are included with each EDS kit Several EDS units can share a single cylinder and pr...

Page 2: ...yed mode will arm the EDS unit to delay delivering oxygen until it is at a pressure altitude of 10 000 ft This is suitable for day time fight operations The power ON OFF switch makes connects and brea...

Page 3: ...e lapse rate curve that starts at sea level and lowers towards a partial pressure representing some very high altitude i e 100 000 ft The spa curve assumes that at sea level the barometric pressure is...

Page 4: ...ylinder The low pressure service line c is a high quality polyurethane line that is kink proof and flexible under varying temperatures The cannula and service line connects to the EDS unit via Quick C...

Page 5: ...ethane line without pushing in the collar It will damage the connector See figures below DO NOT ATTEMPT TO REMOVE REGULATOR FROM CYLINDER WHILE UNDER PRESSURE Doing so will destroy the O ring on the r...

Page 6: ...have their own nasal cannula and face mask In addition replacement of the nasal cannula should be done if it has become soiled or damaged in any way The flow fault alarm will respond to the following...

Page 7: ...the inside diameter of the 6mm outlet tube on the EDS unit 3 With the EDS unit on and the battery test button depressed turn on the cylinder valve slowly to allow gas to flow backwards through the ED...

Page 8: ...nto one standard cannula This allows the pilot to simply throw an on off switch to bypass the EDS unit then having the ability to adjust the flowmeter for the altitude to economize on oxygen usage Bec...

Page 9: ...unit The EDS EPS External Power Supply input jack and plug EDS EPS EDS unit 10 26 VDC input strip The EDS EPS with internal noise and glitch filter unit can operate up to six EDS units External Batter...

Page 10: ...C Nom 25 RH 25 C Max 100 RH 50 C near condensing Vibration Random vibration 5 to 500 Hz 15 minutes per axis 2 5 g rms sin wave Operating pressure range pressure altitude Min 3 4 psia 25 C appx 30 000...

Page 11: ...by Mt High E S Co at a nominal charge Before this warrantee can be valid Mountain High Equipment Supply Co must have your owners guarantee registration form properly filled out and in our files Mount...

Reviews: