1.

 

Ensure that Gangway Ramps, overshoe adaptors and Laddersafe platforms are not damaged or 

distorted and that the correct Laddersafe platform, connecting pins and nuts/bolts have been 

provided prior to use (please refer to MGF Technical File). Always replace damaged components. 

2.

 

Always install the Gangway Ramps and the Laddersafe platform from a position of safety. If working 

from an unsupported edge a full risk assessment should be carried out for installation. Once the 

Laddersafe is installed ensure the clamping bolts are fully clamped and it cannot be lifted, slide or 

rotate prior to securing the Gangway Ramp. 

3.

 

Ensure the Gangway Ramp is securely connected to the Laddersafe platform and that all 20mm 

diameter pins are secured using a r-clip and the supplied securing plate. 

4.

 

Ensure when connecting Gangway ramps together than the M16 nuts and bolts are sufficiently 

torqued and that retaining clips are provided for the integrated pins. Gangway Ramps should be 

connected together prior to securing to the Laddersafe platform. 

5.

 

MGF Gangway Ramps are modular and no more than 3 ramps should be connected together. 

6.

 

The maximum achievable angle of 17.5° must not be exceeded, which can cater for a maximum 

vertical height of 0.5m per ramp, up to a maximum of 1.5m for 3 connected ramps.  

7.

 

MGF Gangway Ramps are designed for man access to an MGF Laddersafe system and should only be 

used by a single person and should not be used to transport/store equipment. 

8.

 

Laddersafe platforms should only be fitted to MGF excavation support systems using the clamps 

specified. The customer must ensure that these support systems are installed in accordance with MGF 

guidelines and are sufficiently robust and stable to act as an effective edge protection support. 

9.

 

It is recommended that 2 operatives are used to install the Gangway Ramp overshoe adaptor and that 

this is installed prior to installing the Laddersafe platform onto the sheets. 

10.

 

Gangway Ramp overshoe adaptors must only be affixed to the back face (retained side) of the 

Laddersafe platforms. Gangway Ramps are not designed for access within the excavation – and are 

only suitable for access to a Laddersafe platform should the upstand be restrictive otherwise, or the 

ground around the installed Laddersafe platform be sloping away from the sheets/box panels or be of 

a poor quality. 

11.

 

Be careful of finger trap hazards during the installation, ensure suitable PPE is worn throughout the 

installation and assembly. 

12.

 

Always consult with MGF for suitability of the system for any specific installation. MGF Laddersafe 

must not be clamped to trench sheets less than 6mm thick, or piles in pure cantilever or cantilevering 

more than 1.5m above a waler rail/brace. In addition, it is essential that the excavation support 

system (that the clamp is attached to) is installed robustly and fully supported by the ground (no 

voids/weak ground present). 

13.

 

Take care when storing Laddersafe and Gangway Ramps onsite as they can be easily damaged. Always 

stack components on timbers and lift using suitable chains/plant. 

14.

 

Ensure that the Gangway Ramp is adequately footed before use on firm, level ground and that the 

Ramp cannot sway, vibrate or deflect excessively during use. 

15.

 

Prior to use it is recommended to use the supplied safety chain to close of the gap between the 

Gangway Ramp handrail and the handrail on the Laddersafe platform. 

16.

 

Removal is a reverse of installation. 

 

 

 

Summary of Contents for UG-015

Page 1: ...0 UG 015 MGF Gangway Ramp User Manual Issue 1 17 05 21 ...

Page 2: ...nts 1 0 INTRODUCTION 2 2 0 FEATURES 2 3 0 SPECIFICATION 3 4 0 Technical Points 5 5 0 SAFETY 7 6 0 PARTS DESCRIPTION 7 7 0 Pre install Set UP Installation 8 8 0 Required Checks 12 9 0 Removal 12 10 0 Product Notes 13 ...

Page 3: ...d lengths of ramp required Each 1 5m long ramp can cater for a maximum 0 5m upstand 3No ramps max can be connected 2 0 FEATURES Enables safe access to a Laddersafe platform when access would otherwise be restrictive either by being installed on an upstand or installed around bad ground which is sloped falling away around the shoring Via the use of adaptors the ramps can connect to the back face of...

Page 4: ...G 015 3 0 SPECIFICATION Length 1500mm 1 5m Max Load 1 persons max 150kg or 1 5kn M2 UDL Unit Weight 128kg Construction material Steel Lifting tether points 4 off 1000kg ea lug Gangway Ramp Unit Dimensions ...

Page 5: ...4 UG 015 Overshoe Adaptor dimensions Over shoe weight 24kg ...

Page 6: ...uts and plain washers 5 0 SAFETY Should questions regarding this manual arise contact MGF Proper shoring and safety precautions must be in place if working below ground level Wear appropriate personal safety equipment including but not limited to hardhat safety boots safety glasses and gloves Cover exposed skin while working on operating the equipment Avoid loose clothing jewellery hair or anythin...

Page 7: ...weights using adequate lifting equipment and good manual handling practices where appropriate Use suitably rated chains when lifting the item into position Always use all four lifting points provided and do not lift the item by any other features than its designated lift points ...

Page 8: ...Flange Lifting Point typ 4 pos Female connecting blade and keeper plate Male connecting pin Hand Rail Knee Rail Operative Lift handle Fixing Pivot plate Pivot plate lock pin Ramp Attachment Point Pivot plate operative lift handle Location plate ...

Page 9: ...unlocked depending on operator preference With two operatives one holding each of the operative lift points orientate the over shoe so the ramp attachment points are facing out from the dig Lift the overshoe over the Laddersafe platform Both pivot plates should be rotated to close and engage fully over the platform chassis Each operative should transfer the load so they move from holding the opera...

Page 10: ...s one each side of the ramp will be required Remove the r clip and take off the loose Keeper plate Lift the ramp and manoeuvre so that the female blade on the ramp locates over the ramp attachment bar on the overshoe or platform Fit the keeper plate over the connection and re fit the r clip Test that the ramp cannot be lifted or knocked off the connection Pivot plate fully engaged and locked Locat...

Page 11: ...the platform handrail using the half swivel scaffold connector bracket Complete this for both handrails Check platform door functionality Note if door operation is obstructed the door should be moved from the platform and attached to the ramp instead Handrail gaps to be bridged using chain and connectors supplied Door can be moved to hinge from ramp handrail if operation is obscured ...

Page 12: ...manoeuvre so that the female blade on the ramp locates over the ramp attachment bar on the adjacent platform Fit retaining bolts through connecting flanges on joined ramps 4 off M16x50 ISO4017 bolts 8 washers and 4 off M16 Nyloc nuts are required to do this Fit the keeper plate over the connection and re fit the r clip Test that the ramp cannot be lifted or knocked off the connection Once connecte...

Page 13: ...sition and secured with r clips if applicable Check Bolted connections are present and tight Check doors operate properly and are secure Check Lift points are undamaged and fit for use Check for distortions and bending in chassis handrails Report any damage 9 0 Removal Removal is a reverse of fitting operation Ensure all items supplied with are returned to MGF post hire otherwise charges will be m...

Page 14: ...hat these support systems are installed in accordance with MGF guidelines and are sufficiently robust and stable to act as an effective edge protection support 9 It is recommended that 2 operatives are used to install the Gangway Ramp overshoe adaptor and that this is installed prior to installing the Laddersafe platform onto the sheets 10 Gangway Ramp overshoe adaptors must only be affixed to the...

Reviews: