background image

MGE UPS SYSTEMS

Pulsar ESV 8+

Rack

/11+

Rack

/14+

Rack

/22+

Rack

86-153523-00

12

introduction of Pulsar UPS

benefits

Network servers and data are very sensitive to
electrical disturbances of all types including out-
ages, brownout, voltage sags, interference, etc.
The origins of disturbances also vary, ranging from
atmospheric phenomena such as lightning or frost,
to near-by devices generating interference such as
elevators, copiers and machine-tools, not to men-
tion human errors such as the accidental pulling
out of power cords or tripping of circuit breakers.
The consequences of disturbances on computer
systems range from damage to hardware (power
supplies, hard disks) to the loss of data.

Pulsar ESV+

Rack has been specially designed to

protect network servers and all other connected
devices that are sensitive to electrical distur-
bances. Pulsar ESV+

Rack adds fault-tolerance to

the power source supplying your server.
Pulsar ESV+

Rack is designed as a compact unit

that silently protects your electrical devices.
Because of its backup battery, Pulsar ESV+

Rack

protects your system for several minutes (see the
"characteristics" section) in the event of a power
failure. A built-in filtering system protects connect-
ed devices from line interference. Finally, to
counter voltage sags or spikes, Pulsar ESV+

Rack

uses voltage compensation circuits ("booster" and
"fader" modes) to guarantee a stable supply of
clean power.
As standard, Pulsar ESV+

Rack offers the

PowerShare function that was previously available
only on large UPSs. Power outputs may be
remotely controlled, thus making possible sequen-
tial start-ups of various devices, selective load
shedding in the event of an overload and priority
management near the end of battery power to pro-
tect the most sensitive load.

options

UM Sensor environment measurement unit:

compatible with SNMP or Solution PacTM, this
unit measures the temperature and the relative
humidity in the room where the Pulsar is installed.
Eight relay contacts are provided to transmit sig-
nals to an administration platform, in the form of
voltage free contacts to enable monitoring of (fire
alarm, climate control fault, intrusion, etc.);

additional communications options:

SNMP administration: MGE has the most com-

plete offering for the administration of a group of
UPSs using the SNMP protocol with different net-
work-connection modules (SNMP card or proxy
software), supervision modules (application for
NMS platforms such as HP OpenView or C.A.
UNICENTER TNG) and a file-closing module (UM
Client).

SNMP card: this card, inserted into your UPS,

can establish a direct Ethernet network connection
for your UPS. It can then be temporarily managed
using SNMP or the various software modules of
Solution-Pac. The MGE UPS SYSTEMS offering
complies with RFC 1628 specifications (IETF) and
was certified by the InterWorking Labs during the
Test Summit in June 1994;

status information card: this option provides

you with 3 data elements on voltage-free contacts:
operating on battery, low battery warning, operat-
ing on utility power. This card can be used with
the UPS driver of IBM AS/400.

Contact your reseller for further information on
these options.

(*) CD-ROM : EMB/ESVPLUS/CONFIG

Pulsar ESV+

Rack offers a number of functions

and characteristics intended to simplify power
management:

automatic battery test carried out periodically. In

the event of a fault, a LED provides enough
advance warning for battery replacement;

LEDs on the front signalling all types of faults

and alarms;

bar graph continuously indicating the battery

charge level or the computer-application load level;

environment friendly: all components are recy-

clable and an electronic power-saver device
reduces consumption if the UPS is not active for a
period exceeding five minutes;

Pulsar ESV+

Rack incluses user-replaceable

batteries, no need to power off connected equip-
ments to replace them;

ESV Driver software is part of our CD-ROM 

(*)

.

It lets you edit the default parameters of Pulsar to
ideally match your requirements;

Pusar ESV+

Rack is Plug and Play: its installa-

tion on Windows 95/98 is fully automatic;

advanced operation and monitoring of Pulsar

are achieved by means of the Solution-Pac
CD-ROM included in your package. To learn more
about all the advanced features offered (system
shutdown, remote monitoring, SNMP administra-
tion,…) please view the navigator tool of the CD-
ROM;

network protection is built-in to ensure safe data

transmission.

Summary of Contents for Pulsar ESV 11+Rack

Page 1: ...user manual Pulsar ESV 8 Rack 11 Rack 14 Rack 22 Rack 1 2 www mgeups com...

Page 2: ...ou require assistance Yours truly MGE UPS SYSTEMS Federal Communications Commission FCC Statement Note this equipment has been tested and found to comply with Part 15 of the FCC Rules These limits are...

Page 3: ...et shall be near the equipment and easily accessible To isolate Pulsar from AC input turn unit off and remove the plug from the utility power outlet if Pulsar is to be stored for a long time it is rec...

Page 4: ...MGE UPS SYSTEMS Pulsar ESV 8 Rack 11 Rack 14 Rack 22 Rack 86 153523 00 4...

Page 5: ...MGE UPS SYSTEMS Pulsar ESV 8 Rack 11 Rack 14 Rack 22 Rack 86 153523 00 5 general contents discover Pulsar 6 illustrations and features key diagram introduction getting started operation 11...

Page 6: ...2 Rack 86 153523 00 6 front view of ESV 8 Rack 11 Rack 14 Rack 22 Rack rear view of ESV11 Rack 14 Rack 1 2 MGE UPS SYSTEMS Inc Vac IN 8 15 10 7b 7a 7 6 9 17 5 16 12 1 2 1a 1b 1c 1d 1e 1f 1g 2 3 MGE UP...

Page 7: ...00 7 13 The indispensable companion sofware for your UPS L indispensable compl ment logiciel de votre onduleur solution pac rear view of ESV8 Rack 1 2 MGE UPS SYSTEMS Inc T 10A 125V I max 6 5A Vac OUT...

Page 8: ...ator light flashing quickly only overload 1d yellow indicator light flashing quickly only operating on booster or fader mode 1e yellow indicator light flashing quickly only plug 2 not powered 1f yello...

Page 9: ...on cards key to diagrams page 6 to 8 2 function button switches off audio warning device or measures load charge percentage with utility power 3 ON OFF switch 4 utility input receptacle 5 utility powe...

Page 10: ...tomate system shutdown supervise and remotely control the UPSs MGE UPS SYSTEMS created Solution PacTM for this purpose Solution PacTM combines all these func tions in a single CD ROM usable in local o...

Page 11: ...liminary checks 13 connections 13 power connections 13 serial connections 13 computer network protection 13 communication 14 operation 15 starting up with utility power 15 starting up without utility...

Page 12: ...e alarm climate control fault intrusion etc additional communications options SNMP administration MGE has the most com plete offering for the administration of a group of UPSs using the SNMP protocol...

Page 13: ...onnect the other end to a serial port of a computer system computer network protection If you wish to use the network line filtering functions Ethernet for example use a cable of the RJ45 type Connect...

Page 14: ...To install ESV Driver connect the serial cable supplied to COM1 to COM4 set up by ESV Tuner seri al port of your computer equipped with Windows 3 1 or 95 98 on the one end and to the serial Pulsar ES...

Page 15: ...es are not powered normal operation indicator lights and audio warning device test press button on off press button 3 1 sec automatic sequence your main devices are supported by the battery Output rec...

Page 16: ...d normal operation with battery autonomy indicator lights and audio warning device test press button 3 1 sec automatic sequence your main devices are supported by the battery Output receptacles 1 and...

Page 17: ...power the fader and booster functions are used to keep the output voltage range Umax Umin compatible with the supply operating range of your application this operating range can be configured via the...

Page 18: ...the utility power returns Pulsar switches to normal operation x min x min 5 min 0 min if Pulsar is operating off load device switches off Pulsar switches off automatically low battery warning indicati...

Page 19: ...reset ther mal breaker 6 re start Pulsar A battery test is carried out while Pulsar is in start up phase then automatically every 7 days overhaul times adjustable using ESV Driver If a battery fault...

Page 20: ...to avoid any data loss use a screwdriver to remove the cover on the right side of the UPS ESV Rack use a screwdriver to remove horizontal metal plate holding the batteries For ESV22 Rack remove termi...

Page 21: ...s with load on battery voltage V single phase 120V 5 frequency F 50Hz 60Hz 1Hz auto selection output specifications with load on utility power voltage V see normal operation with utility power present...

Page 22: ...k battery back up time Pulsar ESV 11 Rack 14 Rack battery back up time Pulsar ESV 22 Rack battery back up time t mn 0 2 tower servers desktop server tower server external mass storage tower server 12...

Page 23: ...ance of original two 2 year warranty or 90 days whichever is greater Customer must first obtain a Return Material Authorization number RMA from MGE s Sales Administration department The RMA must be cl...

Page 24: ...Product names mentioned herein may be trademarks and registered trademarks of their respective companies Published by MGE UPS SYSTEMS 02 99 Austria 0660 6215 Belgium 0800 7 2189 China Hong Kong 852 2...

Reviews: