background image

MFJ-2010 Instruction Manual 

                        Ultralite OCFD

 

Stealth Installation 

Support with dark-colored Dacron or nylon cord (1/8” is good). Because 
the matching system is located at the feed point and SWR along the 
coax is typically low, you may install your antenna at a relatively long 
distance from the operating location. This approach is especially 
desirable for condo or apartment installations to keep the antenna out of 
sight and to reduce interference from consumer electronic devices in 
neighboring units. Use RG-58 type coax for the antenna drop and 
transition to RG-8 low-loss direct-burial cable for the building run.  
 

Power Rating 

The MFJ-2010 is rated for 300-Watts PEP on SSB and CW. However, 
this rating may be adjusted when known feedline losses are present. For 
example, if your coax has a calculated loss of 3-dB on a given band, you 
may safely run up to 600 Watts PEP without damaging the matching 
network which is located at the far end of the cable. However, for modes 
with high power densities such as RTTY, SSTV, and AM, reduce the 
300-Watt rating by at least 50% to avoid excess heat buildup inside the 
antenna’s small unventilated matching enclosure.  
 

SWR 
 

The sample SWR plots shown below were taken through 60 feet of low-
loss (RG-8X) cable with the antenna mounted 45 feet above ground in a 
typical back-yard residential installation. 
 

                      

1.5:1

2:1

1:1

7.0

7.2

7.1

7.3

1.5:1

2:1

1:1

14.0

14.2

14.1

14.3

14.35

1.5:1

2:1

1:1

28.0

28.4

28.2

28.6

28.7

1.5:1

2:1

1:1

50.0

50.4

50.2

50.6

40 Meters

20 Meters

10 Meters

6 Meters

 

Summary of Contents for UltraLite MFJ-2010

Page 1: ...UTION Read All Instructions Before Operating Equipment MFJ ENTERPRISES INC 300 Industrial Park Road Starkville MS 39759 USA Tel 662 323 5869 Fax 662 323 6551 COPYRIGHT 2009 MFJ ENTERPRISES INC C Model...

Page 2: ...manuals documents positional handbooks or other official publications The copy of this manual provided to the customer will not be updated to reflect current data Customers using this manual should r...

Page 3: ...50 Ohm coax cable that is consistent with your station s output power RG 58 or RG 8X Mini 8 cable is good for low power operation up to 100 Watts The antenna s feed block accepts a standard PL 259 co...

Page 4: ...upports are too close together for installing full length the insulators provide the option to droop one or both antenna legs by a few feet Feed excess wire through the stress relief holes and re clam...

Page 5: ...Watts PEP on SSB and CW However this rating may be adjusted when known feedline losses are present For example if your coax has a calculated loss of 3 dB on a given band you may safely run up to 600 W...

Page 6: ...anual If the manual does not reference your problem or your problem is not solved by reading the manual you may call MFJ Technical Service at 662 323 0549 or the MFJ Factory at 662 323 5869 You will b...

Page 7: ...able by calling the Service Department at 662 323 0549 or the MFJ Factory at 662 323 5869 4 This warranty does not apply to kits sold by or manufactured by MFJ Enterprises Inc 5 Wired and tested PC bo...

Page 8: ...MFJ 2010 Manual Version 2B Printed In U S A 300 Industrial Park Road Starkville MS 39759 MFJ ENTERPRISES INC...

Reviews: