04
1. Delivery condition
The
E-NERGY CARBON
panel heating system can be used as a full heating system, auxiliary heating or for
surface tempering can be used in the renovation (e.g. mould prevention).
1.1 Scope of delivery
• E-NERGY CARBON power supply unit BASIC TT
• Installation instructions & operating manual
The following additional products are required for the complete E-NERGY CARBON system:
• Assembled heating foils from 60 to 290 W/m²
• E-NERGY CARBON room thermostat
2. Information for users
Please read these operating instructions carefully before installation and follow the instructions. The
E-NERGY
CARBON
system can be used by children aged 8 years and older and by persons with reduced physical, sensory or
mental abilities or lack of experience and knowledge, if have been supervised or instructed in the safe use of the
device and the resulting understand the resulting dangers. Children must not play with the device. Cleaning and
user maintenance must not be carried out by children without supervision.
A copy of the operating instructions must be kept in the circuit distribution box. In case of change of ownership the
Please inform the subsequent owner about the installation. In humid/wet rooms DIN VDE 0100 part 701
be taken into account. If the
E-NERGY CARBON
heating foil is installed under e.g. a tiled floor (preferably
underneath the sealing) in a humid/wet area (e.g. shower), this area does not count as protection area 0, 1 or 2
according to DIN VDE 0100 part 701. Installation is permitted under these conditions.
2.1 Safety instructions
• Please read this manual carefully and completely before you start the installation.
• Transport: To protect all parts from damage, they should remain in their original packaging until they reach the
installation site. Internal parts can be damaged by shock and fall.
• Damaged equipment or parts must not be put into operation.
• Do not remove the safety labels and type plates.
• The individual components may only be installed in closed rooms.
• All assembly and installation work must always be carried out in a de-energised state.
• he circuit for connecting the power supply unit must be sufficiently dimensioned and fused for installation.
When operating the heating system, this circuit must not be overloaded.
• The device is not ready for operation when delivered and must first be connected by a qualified electrician.