Scribe SA Standalone Series Operator’s Guide
Document Revision: 03/24/06
Page 17
•
Pressing the “4” key on the keypad will first display the option for
importing PRN files.
•
Pressing “Stop/No” Button will now display
•
When selected, the
Loader Test Mode
function allows you to
manually control the robotic functions of the system, this features
aids you in troubleshooting the robotic functions. The commands are
explained below.
•
“C”- calibrates the picking arm
•
“I”- loads a disc into the open drive from the input spindle
•
“A”- unloads the disc and places it on the accept spindle.
•
“R”- key puts the disc in the rejection area in front of the drive
tower.
•
“J” – retrieves a disc from the input hopper and hovers above
an open drive tray.
•
Press the “Stop/No” key to exit