APPENDIX A: CAL SPECIFICATIONS
38
AUDIO / CONTROL
Analog Audio
(3) Phoenix 6-pin male connectors for balanced audio input and loop output
Digital Audio
(1) Phoenix 6-pin male connector for AES/EBU input
Note:
The connector’s bottom three pins are not used.
Ethernet and AVB
AVB-enabled Ethernet ports for integrated audio streaming, beam control and RMS monitoring via
Compass control software. Supports communication of AVB timing data and audio signals via AAF packets
(AVTP Audio Format) and communication of AVB clock signals via CRF packets (Clock Reference Format).
Processing
Mute, gain, 5-band parametric EQ, and delay, stored in four onboard presets
Note:
Processing and beam settings can be edited in Compass control software and saved in four onboard
presets.
Logic I/O
Phoenix 6-pin male connector, recalls onboard presets, reports relay closures (and openings) for fault
reports; Phoenix 5-pin male connector, triggers emergency mute and input override
Display
OLED button displays the CAL loudspeaker's network addresses during startup or when the button is
pushed
AC POWER
Connector
powerCON 20
Rated Voltage Range
100–240 V AC, 50–60 Hz
Turn-on and Turn-off Points
90 V AC turn-on; 264 V AC turn-off
CURRENT DRAW
Idle
CAL 96
1.98 A rms (115 V AC)
1.63 A rms (230 V AC)
2.32 A rms (100 V AC)
CAL 64
1.24 A rms (115 V AC)
0.99 A rms (230 V AC)
1.42 A rms (100 V AC)
CAL 32
0.58 A rms (115 V AC)
0.45 A rms (230 V AC)
0.65 A rms (100 V AC)
Maximum Long-Term
Continuous (>10 sec)
CAL 96
8.3 A rms (115 V AC)
4.2 A rms (230 V AC)
9.4 A rms (100 V AC)
CAL 64
6.1 A rms (115 V AC)
3.1 A rms (230 V AC)
6.9 A rms (100 V AC)
CAL 32
3.3 A rms (115 V AC)
1.7 A rms (230 V AC)
3.7 A rms (100 V AC)
Burst (<1 sec)
CAL 96
14.7 A rms (115 V AC)
7.3 A rms (230 V AC)
18.5 A rms (100 V AC)
CAL 64
10.8 A rms (115 V AC)
5.4 A rms (230 V AC)
13.6 A rms (100 V AC)
CAL 32
5.9 A rms (115 V AC)
2.9 A rms (230 V AC)
7.4 A rms (100 V AC)
Maximum Instantaneous
Peak
CAL 96
33 A peak (115 V AC)
18 A peak (230 V AC)
40 A peak (100 V AC)
CAL 64
24 A peak (115 V AC)
13 A peak (230 V AC)
29 A peak (100 V AC)
CAL 32
13 A peak (115 V AC)
7 A peak (230 V AC)
16 A peak (100 V AC)
Summary of Contents for CAL 32
Page 6: ...IMPORTANT SAFETY INSTRUCTIONS vi...
Page 8: ...CONTENTS viii 42...
Page 14: ...CHAPTER 2 POWER REQUIREMENTS 14...
Page 22: ...CHAPTER 3 CAL USER PANEL 22...
Page 28: ...CHAPTER 5 COMPASS CONTROL SOFTWARE 28...
Page 43: ......