3
Installation
page 19
ELC X-Series-V1.3-09.16-GB
subject to technical alterations
X805:
Connector pin assignment:
Connection torque:
min. 0.22 Nm
max. 0.25 Nm
PIN-assignment X805:
Designation
Number Description
technical
Interconnection
IN
X805.1
Continuous contact, connected
to X806.1
max. 1A, 24V
Safety NC 1
X805.2
Feedback contact 1 safety relay Normally closed contact
24V / 1A
Safety NC 2
X805.3
Feedback contact 2 safety relay Normally closed contact
24V / 1A
Shield
X805.4
Continuous contact, connected
to X806.4, usable for shield of
the control cable
max. 1A, 24V
24V_IN
X805.5
Connection for external supply
voltage, connected to X806.5
24V DC ± 10%, current
consumption of the ELC control
circuitry see chapter 6
24V_GND
X805.6
Common (GND),
connected to X806.7
GND
not connected
X805.7
Not connected
UV Select NO 2 X805.8
Feedback contact 2 UV-select
Normally open contact 24V/1A
UV Select NO 1 X805.9
Feedback contact 1 UV-select
Normally open contact 24V/1A
UV Ready NO 2 X805.10 Feedback contact 2 UV-ready
Normally open contact 24V/1A
UV Ready NO 1 X805.11 Feedback contact 1 UV-ready
Normally open contact 24V/1A
1