background image

 

16 

 

Replacement parts 

 
 
 

Position 

Code 

Description 

Qty. 

Application for 

Model 

BAS045 

Square Plastic Base 

01 

LQL.4/6/8/10 

ALF025 

Square Aluminum Base 

01 

LQ4/6/8/10 

GAB090 

Cabinet 

01 

MTE260 

Electric Motor 1/2 cv 60 Hz 127 V 

01 

LQ/LQL.4/6 

MTE261 

Electric Motor 1/2 cv 60 Hz - 220 V 

01 

LQ/LQL.4/6 

MTE027 

Electric Motor 1/2 cv 50 Hz - 220 V 

01 

LQ/LQL.4/6 

MTE258 

Electric Motor 3/4 cv 60 Hz - 127 V 

01 

LQ/LQL.8/10 

MTE259 

Electric Motor  3/4 cv 60 Hz - 220 V 

01 

LQ/LQL.8/10 

MTE087 

Electric Motor  3/4 cv 50 Hz - 220 V 

01 

LQ/LQL.8/10 

RBT002 

Rivet 

08 

SUC017 

Plastic Cup Holder 

01 

LQL.4/6/8/10 

ALF204 

Aluminum Cup Holder 

01 

LQ4/6/8/10 

CJT689 

Full Coupling 

01 

6.1 

ADA022 

Coupling 

01 

6.2 

PRN002 

Screw 

01 

CJT845 

Full Stainless Steel LQ/LQL Cup.4 

01 

LQ/LQL.4 

CJT847 

Full Stainless Steel LQ/LQL Cup.6 

01 

LQ/LQL.6 

CJT849 

Full Stainless Steel LQ/LQL Cup.8 

01 

LQ/LQL.8 

CJT852 

Full Stainless Steel LQ/LQL Cup.10 

01 

LQ/LQL.10 

7.1 

TAP103 

Overcap of the blenders 

01 

7.2 

TAP157 

Black Plastic Cover - LQ/LQL.4/6 

01 

LQ/LQL.4/6 

TAP158 

Black Plastic Cover - LQ/LQL.10/8 

01 

LQ/LQL.10/8 

7.3 

COP123 

Pointed Cup - LQ / LQL.4 

01 

LQ/LQL.4 

COP126 

Dotted Cup - LQ / LQL.6 

01 

LQ/LQL.6 

COP129 

Pointed Cup - LQ / LQL.8 

01 

LQ/LQL.8 

COP132 

Pointed Cup - LQ / LQL.10 

01 

LQ/LQL.10 

7.4 

CJT690 

Full Bearing of the Cup - LQ / LQL.4/6 

01 

LQ/LQL.4/6 

CJT850 

Full Bearing of the Cup - LQ / LQL.8/10 

01 

LQ/LQL.8/10 

7.4.1 

POS015 

Hexagonal Nut  

01 

7.4.2. 

LMT002 

Stainless Steel Blade 

01 

LQ/LQL.4/6 

LMT037 

Stainless Steel Blade 

01 

LQ/LQL.10/8 

7.4.3 

VRG002 

V'ring 

01 

7.4.4 

ARE007 

Celeron Graphite Washer Ø 8 

02 

7.4.5 

POE010 

Bearing Nut 

01 

7.4.6 

ARE018 

Celeron Graphite Washer  Ø 1/4" 

01 

7.4.7 

CJT140 

Bearing with Bushing 

01 

7.4.8 

EIX205 

Axis of the Cup 

01 

PRS008 

Hexagonal Screw  

03 

ARL003 

Flat washer. 

03 

10 

CRC477 

Closing Plate Key Selector 

01 

11 

CBE020 

Electrical Cable - Type 1 

01 

CBE007 

Electrical Cable - Type 2 

01 

CBE001 

Electrical Cable - Type 4 

01 

12 

TCE021 

Print cable  

01 

13 

CHE064 

On/Off Switch 

01 

14 

BCH057 

Celme Key frame 

01 

15 

PEP014 

Square Base Blender Foot 

04 

16 

TCE013 

Female Terminal (Yellow) 

01 

17 

TCE004 

Terminal Fit (Blue) 

04 

18 

CBE092 

V/A Amendment Terminal (Earth) 

01 

 
 

 
 

Summary of Contents for LQ.10 Series

Page 1: ...1...

Page 2: ...nd Maintenance 10 5 1 Cleaning Procedures and Products Used 10 5 2 Maintenance and Procedures in Case of Malfunctions 11 6 Annexes 13 Electrical Schematic 110 V 60 13 Electrical Schematic 220 V 50 Hz...

Page 3: ...ing that they lock in the moving parts of the machine The operator must always be aware of situations that can cause a risk of accidents and avoid them For example avoid working with loose uniform sle...

Page 4: ...lkalis oxy salts etc Note stainless steel 304 is attacked by sulfuric acid and also cannot withstand hydrochloric acid diluted sulfuric acid chlorides and halides in general Cabinet made of 430 stainl...

Page 5: ...220M604 230x840x230 12 1 220 5 1 10 LQL4110M604 230x615x230 9 4 110 6 8 4 LQL4220M501 230x615x230 9 7 220 3 5 4 LQL4220M502 230x615x230 9 7 220 3 5 4 LQL4220M504 230x615x230 9 7 220 3 5 4 LQL4220M604...

Page 6: ...manual available to the professionals who carry out the installation To ensure correct operation and safety the machine must be positioned in an airy environment and on a sufficiently wide level dry a...

Page 7: ...anufacturer shall not be liable for any direct or indirect damages caused by non compliance with these standards and other instructions presented in this manual 4 Use of the Device 4 1 Utility This ap...

Page 8: ...ched to the glass Make sure that the cup is firmly inserted in the coupling and cup holder Also check that the supply voltage of the device 110 V ou 220 V complies with that of the power grid After ve...

Page 9: ...cessed remove only the overcap Never turn on the device with the cup uncovered and also don t remove the cup while the device is in operation ATTENTION Do not put your fingers hands or objects such as...

Page 10: ...om the cup follow the instructions below 1 Insert the cup into the coupling and cup holder 2 Add lukewarm water and a few drops of neutral detergent into the glass 3 Place the cover and turn the devic...

Page 11: ...kdowns that could occur Examples include checking for extraneous noise loss of power of the appliance the non performance by the appliance of the service to which it proposes among others Actions such...

Page 12: ...n item related to the safety of the device is removed e g when performing maintenance put it back in its proper place and confirm that it is performing its function correctly When a breakdown or non c...

Page 13: ...cheme Voltage 110 V 60 Hz ATTENTION The ground connection varies according to the type of plug For electrical installation observe the current standards of the country especially with regard to ground...

Page 14: ...above Electrical Schematic white wires are represented by pink ATTENTION The ground connection varies according to the type of plug For electrical installation observe the current standards of the cou...

Page 15: ...15 Exploded Design...

Page 16: ...TAP157 Black Plastic Cover LQ LQL 4 6 01 LQ LQL 4 6 TAP158 Black Plastic Cover LQ LQL 10 8 01 LQ LQL 10 8 7 3 COP123 Pointed Cup LQ LQL 4 01 LQ LQL 4 COP126 Dotted Cup LQ LQL 6 01 LQ LQL 6 COP129 Poi...

Page 17: ...17 Notes...

Page 18: ...18 Notes...

Page 19: ...19...

Page 20: ...ara Gastronomia Ltda CNPJ 11 193 347 0001 14 CREA 131726 3 Rod Ant nio Heil KM 23 N 5825 Bairro Limoeiro CEP 88352 502 Brusque SC Brazil Phone fax 55 47 3251 5555 Website www metvisa com br E mail sac...

Reviews: