14
6 DA 70 en
Loose and remove the short hexagon screws (23, 24,
diaphragm case bolts) and the hexagon nuts (25).
Loose and remove the the long hexagon screws (24,
tension bolts) and the hexagon nuts (25). in cross
steps to release spring tension gradually.
Remove the upper case (20).
Loose the stem nut (33) and remove the lock washer
(33a).
Remove the stem rod plate (16) with inserted o-ring
(17) from top stem (18).
Remove the diaphragm (6) and diaphragm plate (13)
and stopper (15) from the top stem (18).
Remove the spring seats (11) and springs (12).
Mount the stem rod plate (16) with inserted o-ring
(17) on the top stem (18).
Mount the the diaphragm (6) and diaphragm plate
(13).
Mount the the stopper (15) on the top stem (18).
Mount the lock washer (33a) and stem nut (33) and
tighten.
Mount the spring seats (11) and springs (12).
Mount the upper case (20).
Replace and tighten the long hexagon screws (24,
tension bolts) and hexagon nuts (25) in equal steps
until the cases meet.
Replace and tighten the remaining the short hexa-
gon screws and nuts.
Mount the vent cap (34) on the upper case (20) for
prevent go water, dirty particles into the actuator.
To connect the related instrument fitting and tub-
ings on the bottom side of lower case (10).
4.7.2
Change of the actuator action: VDR, Air
to open --> VDD, Air to close
See Fig. 5 and Exploded view.
We recommend that all seals be replaced when the
actuator has been dismantled for servicing.
The actuator must be depressurized and the supply
air pipes disconnected.
Detach the actuator.
Check that the actuator has been depressurized, and
remove air tubing from the lower case (10).
Loose and remove the short hexagon screws (23, 24,
diaphragm case bolts) and the hexagon nuts (25).
Loose and remove the the long hexagon screws (24,
tension bolts) and the hexagon nuts (25). in cross
steps to release spring tension gradually.
Remove the upper case (20).
Remove the spring seats (11) and springs (12).
Loose the stem nut (33) and remove the lock washer
(33a).
Remove the stopper (15) and the diaphragm plate
(13) and diaphragm (6) from the top stem (18).
Remove the stem rod plate (16) with inserted o-ring
(17) from top stem (18).
Mount the spring seats (11) and springs (12) on the
lower case (10).
Mount the the stopper (15) on the top stem (18).
Mount the diaphragm plate (13) and the diaphragm
(6).
Mount the stem rod plate (16) with inserted o-ring
(17) on the top stem (18).
Mount the lock washer (33a) and stem nut (33) and
tighten.
Mount the upper case (20).
Replace and tighten the long hexagon screws (24,
tension bolts) and hexagon nuts (25) in equal steps
until the cases meet.
Replace and tighten the remaining the short
CAUTION:
Diaphragm case is under spring tension and is equip-
ped with the long hexagon screws (24, tension bolts)
which must be removal last.
CAUTION:
Checking whether scratched on the top stem (18) and
dirty particles inside of the case and the diaphragm
and o-rings before reassembling.
NOTE:
Set the springs so that the coil ends are located toward
the actuator stem center, this will be assures best perfor-
mance of the actuator.
CAUTION:
Do not over tighten the hexagon screws as this could
possibly warp the diaphragm and cases, see torque
values on the table 6.
NOTE:
If actuator is equipped with the handwheel, rotate
handwheel to a 'AUTO' position.
CAUTION:
Diaphragm case is under spring tension and is equip-
ped with the long hexagon screws (24, tension bolts)
which must be removal last.
CAUTION:
Checking whether scratched on the top stem (18) and
dirty particles inside of the case and the diaphragm
and o-rings before reassembling.
NOTE:
Set the springs so that the coil ends are located toward
the actuator stem center, this will be assures best perfor-