![Metso VD Series Installation, Maintenance And Operation Instructions Download Page 8](http://html.mh-extra.com/html/metso/vd-series/vd-series_installation-maintenance-and-operation-instructions_1780195008.webp)
8
6 DA 70 en
Mount the spring seats (11) and springs (12).
Mount the diaphragm plate (13) with the stopper
(15) on the top stem (18).
Mount the replaced diaphragm (6).
Insert the replaced O-ring (17).
Mount the stem rod plate (16) and lock washer (33a),
stem nut (33) and tighten.
Mount the upper case (20).
Tighten the long hexagon screws (24, tension bolts)
the hexagon nuts (25) in equal steps until the cases
meet.
Replace the remaining the short hexagon screws
and nuts.
4.3
Replacement diaphragm for VDR,
Air to open
See Fig. 5 and Exploded view.
We recommend that all seals be replaced when the actua-
tor has been dismantled for servicing.
The actuator must be depressurized and the supply air
pipes disconnected.
Detach the actuator.
Check that the actuator has been depressurized, and
remove air tubing from the lower case (10).
Remove the short hexagon screws (23, 24, dia-
phragm case bolts) and the hexagon nuts (25).
Remove the the long hexagon screws (24, tension
bolts) and the hexagon nuts (25) in cross steps to
release spring tension gradually.
Remove the upper case (20).
Remove the spring seats (11) and springs (12).
Remove the diaphragm (6) and the diaphragm plate
(13) with the stopper (15) and O-ring (17) from the
top stem (18).
Replace the U-packing (4) and O-ring (5) in the stem
guide (2).
Mount the stem rod plate, the replaced O-ring (5),
diaphragm (6) and the diaphragm plate (13) with the
stopper (15) the top stem (18). Then, tighten.
Mount the spring seats (11) and springs (12).
Mount the upper case (20).
Tighten the long hexagon screws (24, tension bolts)
the hexagon nuts (25) in equal steps until the cases
meet.
Replace the remaining short hexagon screws and
nuts.
4.4
Operation the handwheel
See Fig. 6 and 7.
Check the current valve position should be 'AUTO'
position (see the stroke indicator, which is open or
close).
Turn over the locking device to release the
handwheel.
Operate the handwheel to be open or close position
--- Manual mode.
Return the stem position to be 'AUTO' position.
Return the locking device to be locked with the
'AUTO' position --- Auto mode.
NOTE:
Set the springs so that the coil ends are located toward
the actuator stem center, this will be assures best perfor-
mance of the actuator.
CAUTION:
Do not over tighten as this could possibly warp the
diaphragm cases.
NOTE:
If actuator is equipped with the handwheel, rotate
handwheel to a neutral position.
CAUTION:
Diaphragm case is under spring tension and is equip-
ped with the long hexagon screws (24, tension bolts)
which must be removal last.
CAUTION:
Checking whether scratched on the stem guide (18)
and dirty particles inside of the stem guide (2) and the
diaphragm and O-rings before reassembling.
NOTE:
Set the springs so that the coil ends are located toward
the actuator stem center, this will be assures best perfor-
mance of the actuator.
NOTE:
Lubricate seal space and new O-ring with Unisilikon L250L
or equal silicone grease.
CAUTION:
Do not over tighten as this could possibly warp the
diaphragm cases.
CAUTION:
Don`t operate the handwheel while the locking device
engaged, it can cause damage.