28
RFC 2544. Parameters Configuration
1200 s).
4.6
Back-to-Back
Figure 4.15. Back-to-Back Measurement Settings
•
Enable this test
— is a flag that turns Back-to-Back (maximum
load) measurement on or off, F2 functional key has the same meaning.
•
Initial frame count (frames)
— the starting length of transmitted
sequence.
•
Step (frames)
— is a step of frame quantity (sequence length) chang-
ing.
•
Trials
— quantity of measurements for each frame size configured.