METRON QA-ST MKII Getting Started Manual Download Page 2

QA-ST MKII – 

Getting Started Guide

 

 

Copyright 

©

 2005 by Fluke Electronics Corporation. All rights reserved. 

 
Fluke Electronics Corporation 
Biomedical Systems (METRON Product Group) 
5200 Convair Drive  
Carson City, NV 89706  

Customer Support and Sales 

Phone (US Toll Free): 800.648.7952 
Phone (Outside the US): 775.883.3400  
FAX: 775.883.9541  
E-Mail: 

[email protected]

  

Internet: 

www.flukebiomedical.com

  

Service 

Phone (US Toll Free): 888.993.5853 
Phone (Outside the US): 425.446.5560 
E-Mail: 

[email protected]

  

 

Notices 

 

Disclaimer 

METRON provides this publication as is without warranty of any kind, either express or implied, including but not limited 
to the implied warranties of merchantability or fitness for any particular purpose. Further, METRON reserves the right to 
revise this publication and to make changes from time to time to the content hereof, without obligation on the part of 
METRON or its local representatives to notify any person of such revision or changes. Some jurisdictions do not allow 
disclaimers of expressed or implied warranties in certain transactions; therefore, this statement may not apply to you. 

 

Limited Warranty 

METRON warrants that the 

QA-ST MKII

 Electrical Safety Tester will substantially conform to published specifications 

and to the documentation, provided that it is used for the purpose for which it was designed. METRON will, for a period of 
twelve (12) months from date of purchase, replace or repair any defective simulator, if the fault is due to a manufacturing 
defect. In no event will METRON or its local representatives be liable for direct, indirect, special, incidental, or 
consequential damages arising out of the use of or inability to use the 

QA-ST MKII

 Electrical Safety Tester, even if 

advised of the possibility of such damages. METRON and its local representatives are not responsible for any costs, loss of 
profits, loss of data, or claims by third parties due to use of, or inability to use the 

QA-ST MKII

 Electrical Safety Tester. 

Neither METRON nor its local representatives will accept, nor be bound by any other form of guarantee concerning the  

QA-ST MKII

 Electrical Safety Tester other than this guarantee. Some jurisdictions do not allow disclaimers of expressed 

or implied warranties in certain transactions; therefore, this statement may not apply to you. 

 

Safety Notice 

The 

QA-ST MKII 

Electrical Safety Tester performs tests in accordance with several electrical safety 

standards. In the process of this testing, voltages of up to 300 Vac may be present in the test leads, outlet, 
and/or enclosure of the Device Under Test. Use all applicable electrical safety measures. 

Summary of Contents for QA-ST MKII

Page 1: ...QA ST MKII Electrical Safety Tester US Model Getting Started Guide...

Page 2: ...ially conform to published specifications and to the documentation provided that it is used for the purpose for which it was designed METRON will for a period of twelve 12 months from date of purchase...

Page 3: ...rement Selection 2 OE Open Earth Test 2 ON Open Neutral Test 2 RM Reverse Mains Test 3 Mains Voltage Test 3 Protective Earth Test 3 Earth Leakage Current Test 3 Enclosure Leakage Current Test 3 Patien...

Page 4: ...t with power 2 Confirm that the only lights illuminated are the two lights in the inlet power indicator boxed in blue If either of these lights is not illuminated or if any other combination of lights...

Page 5: ...ovided test name unit of measure and options Options include assorted user selectable power conditions as well as the AC DC measurement selection AC DC Measurement Selection To select AC or DC measure...

Page 6: ...nt outlet To execute the test and display the results connect the test lead to the enclosure of the DUT and then press the m button below the gnd wire res label Earth Leakage Current Test A ON RM This...

Page 7: ...ient lead to all other patient leads in parallel To select and display the leakage of an individual patient lead to all other leads in parallel repeatedly press the lead to lead button below the patie...

Page 8: ...LEAKAGE CURRENT MEASUREMENTS DC AND AC Range 0 1999 A Accuracy DC and 25 to 1 kHz 2 of reading 3 A Resolution 1 A Test modes AC and DC measurements LEAD ISO MEASUREMENTS Range 0 6000 A RMS Accuracy D...

Page 9: ...462722 Accessories 11042 User Manual CD Part Number 11042 11150 Carrying Case Part Number 2462192 17260 Hard Case Part Number 2462161 17358 Test lead Kelvin cable Part Number 2568891 17024 Universal b...

Reviews: