METRON PS-416M User & Service Manual Download Page 24

 

5-24 

COMPONENT PART 

TYPE/VALUE 

QTY

DIAGRAM REFERENCE 

 

 

 

 

Op.ampl 

LT1013DN8 

IC9, 1C10,  1Cl1,  1C16 

Opto coupler 

6N136HP 

IC12,  1C13,  1C14 

DIA-converter DAC8043FP 

IC15, 

Opto coupler 

VTL5C7  

IC17,  1C18 

V-ref.  

LM-385Z     1V2 

IC19, 

Transistor 

BC547C 

Q1,  Q20 

Diode  

1N4002 

D1 

Diode 

1N4148 

D2,  D3,  D7,  D8  

Zenerdiode 

17Vbip. BZW06-17B 

D4  

Krystall 

8 MHz HC-18/U 

Y1 

Resistor 

20R    1%    0.5W 

R7  

Resistor 

24R9    1%    0.5W 

R9  

Resistor  

34R8    1%    0.5W 

Rll 

Resistor 

35R7    1%    0.5W 

R13 

Resistor 

40R2    1%    0.5W 

R15 

Resistor 

56R2    1%    0.5W 

R75 

Resistor 

75R    1%    0.5W 

R46,  R47,  R48  

Resistor 

84R5    1%    0.5W 

R17  

Resistor 

93R1    1%    0.5W 

R79  

Resistor 

100R    1%    0.5W 

R29  

Resistor 

150R    1%    0.5W 

R85 

Resistor  

174R    1%    0.5W  

R50, R76 

Resistor 

200R    1%    0.5W 

R49 

Resistor 

249R    1%    0.5W 

8  

R63, R64, R65,  R66, R67,  
R69,  R70, R71 

Resistor 

332R    0.10 %    0.5W 

I  

R84 

Resistor 

348R    1%    0.5W 

R19 

Resistor 

365R     1%    0.5W 

R82, R86, R87 

Resistor 

412R     1%    0.5W 

R21 

Resistor 

499R     1%    0.5W 

R52, R54, R56, R58, R60,  
R62 

Resistor 

576R     1%    0.5W 

R23 

Resistor 

1K18     0.50%    0.5W 

R8 

Resistor 

1K33     0.50%    0.5W 

R10 

Resistor 

1K78     0.50%    0.5W 

R12 

Resistor 

2K0        1%    0.5W 

R28, R72, R73, R74 

Resistor 

2K32      0.10%    0.5W 

R83 

Resistor 

3K16      0.50%    0.5W 

R14 

Resistor 

3K57      0.50%    0.5W 

R16 

Resistor 

3K74       1%    0.5W 

R80 

Resistor 

4K75       0.50%    0.5W 

R18 

Resistor 

4K99  1%    0.5W 

R4, R68 

Summary of Contents for PS-416M

Page 1: ...1 1 PS 416M User Service Manual PATIENT SIMULATOR...

Page 2: ...mited Warranty METRON warrants that the PS 416M Patient Simulator will substantially conform to published specifications and to the documentation provided that it is used for the purpose for which it...

Page 3: ...nd Terminals 3 13 3 2 Use 3 14 4 CONTROL AND CALIBRATION 4 17 4 1 Required Equipment 4 17 4 2 Preparation 4 17 4 3 Function Testing 4 17 5 COMPONENT FUNCTIONS AND PARTS 5 21 5 1 Theory of Operation 5...

Page 4: ...1 4 This page intentionally left blank...

Page 5: ...ity representative authorized to process changes and revisions to publications make the pen changes or insert the revised pages ensure that obsolete pages are withdrawn and either disposed of immediat...

Page 6: ...1 6 This page intentionally left blank...

Page 7: ...ht ven tricular one paced and one fetal maternal ECG simulation 1 2 Specifications 1 ECG General Lead Configuration 12 lead simulation derived from one resistively divided analog signal RL RA LA LL V1...

Page 8: ...ivity 5 or 40 V V mmHg Accuracy 1 full scale 1 mmHg Calibrated Rate 80 BPM 7 Dynamic Blood Pressure Selections Atmosphere 0 mmHg Arterial 120 80 mmHg Left Ventricle 20 0 mmHg Right Ventricle 25 0 mmHg...

Page 9: ...Connectors High Level Standard phone jack Low level 10 AHA color coded standard safety banana con nectors with detachable banana to snap adapter Power 9 V alkaline battery or battery eliminator Case...

Page 10: ...1 10 This page intentionally left blank...

Page 11: ...a replacement The customer will not have to wait for a claim to be investigated by the supplier The customer should place a new purchase order to ensure delivery 4 When returning an instrument to MET...

Page 12: ...2 12 This page intentionally left blank...

Page 13: ...s Press the top of the key to increase the value Press the bottom of the key to decrease the value 3 Enter Pressing this stores newly specified waveform value set by the keys 4 High Level ECG Connecto...

Page 14: ...lide switch situated at the bottom right hand corner of the panel The instrument should be switched off when not in use to save the battery A flashing display indicates low battery power 2 Battery Rep...

Page 15: ...e sensitivity switch pVN mmHg must be set to match the input sen sitivity of the patient monitor either 5 or 40 pVN mmHg The wave form is selected and stored in the display Prewired cables P N 17440 a...

Page 16: ...re supplied with the PS 416M P N 17023 Battery Eliminator METRON s AC Adapter plug in power supply transformer allows you to use the PS 416M anywhere a standard electrical outlet is available To attac...

Page 17: ...n of 70mA 20mA 4 3 Function Testing 1 Turn the Power Switch on The LCD display will briefly show the soft ware version number before showing the active ECG function 03 Press the Key Switches beneath t...

Page 18: ...e in position II To measure LL the Lead switch must be in position I Re quirement 1000 ohms 30 ohms 10 Repeat test 9 only this time with Base ohms in position 500 To measure LA the Lead switch must be...

Page 19: ...ence current between TP10 and TP9 nom 0 62v lmV 19 Measure and note the voltage between LL and RA typ 100 V Set the display at 3 and press Enter Measure the voltage once more and adjust P4 until the d...

Page 20: ...4 20 This page intentionally left blank...

Page 21: ...5 2 Functions Description 1 Power Supply The unit is powered from either an internal 9 V battery or an external battery eliminator Diode D1 protects against a wrong polarization Power switch SW1 take...

Page 22: ...ocessor in put E6 via resistor R88 If the power falls below the threshold internally in the processor the program in the processor will cause the display to flash 4 Temperature Output The temperature...

Page 23: ...d from the rest of the equipment to separate several connected instruments galvanically Blood pressure data is transferred serially from the processor to voltage regulator IC5 a 12 bit D A converter T...

Page 24: ...R46 R47 R48 Resistor 84R5 1 0 5W 1 R17 Resistor 93R1 1 0 5W 1 R79 Resistor 100R 1 0 5W 1 R29 Resistor 150R 1 0 5W 1 R85 Resistor 174R 1 0 5W 2 R50 R76 Resistor 200R 1 0 5W 1 R49 Resistor 249R 1 0 5W...

Page 25: ...tor 80K6 1 0 5W 4 R25 R32 R40 R51 Resistor 97K6 1 0 5W 1 R27 Resistor 165K 1 0 5W 2 R41 R88 Resistor 10M 5 0 5W 1 R1 Resistor nettv 47Kx 8 2 RP1 RP2 Potmeter 1K0 1 turn 2 P1 P2 Potmeter 1K 20 turn 1 P...

Page 26: ...57 42 2 IC socket 52 pin PLCC 48 109 41 1 Space bar Ritcho SRS4 4 0 4 Battery el cont S G9312 01 Female 1 J1 Test plug Male 1 J4 Test plug Female 1 J5 Phono socket LPV1120 01 black Female 1 J6 Header...

Page 27: ...5 27 APPENDIX A DIAGRAMS Component Location Diagram Schematic Diagram Part 1 Schematic Diagram Part 2...

Page 28: ...5 28 This page intentionally left blank...

Page 29: ...5 29 Component Location...

Page 30: ...5 30 Schematic Diagram Part 1...

Page 31: ...5 31 Schematic Diagram Part 2...

Page 32: ...5 32 This page intentionally left blank...

Page 33: ...2 8500 Fax 1 616 454 3350 Fax 33 1 6078 6839 Fax 47 7391 7009 E mail metronus aol com E mail metronfrance infonie fr E mail support metron no From name Phone Address Fax Date PS 416M Error Report Prod...

Page 34: ...5 34 This page intentionally left blank...

Page 35: ...1 6078 8899 Phone 47 7382 8500 Fax 1 616 454 3350 Fax 33 1 6078 6839 Fax 47 7391 7009 E mail metronus aol com E mail metronfrance infonie fr E mail support metron no From name Phone Address Fax Date P...

Page 36: ...5 36...

Reviews: