Summary of Contents for Mira P

Page 1: ...Mira P Product Manual 8 0924 8001EN 2019 03 29...

Page 2: ......

Page 3: ...Metrohm AG Ionenstrasse CH 9100 Herisau Switzerland Phone 41 71 353 85 85 Fax 41 71 353 89 01 info metrohm com www metrohm com Mira P Product Manual 8 0924 8001EN 2019 03 29...

Page 4: ...echcom metrohm com This documentation is protected by copyright All rights reserved This documentation has been prepared with great care However errors can never be entirely ruled out Please send comm...

Page 5: ...ers at the workplace 7 2 4 2 Danger from electrical potential 8 2 4 3 Laser safety 8 2 4 4 Warning stickers on the instrument 10 2 5 Responsibility of the operator 11 2 6 Personnel requirement 12 3 Ov...

Page 6: ...ce 41 8 1 Maintenance agreement 41 8 2 Checking and replacing product parts 41 8 3 Cleaning the product 42 9 Disposal 44 10 Technical specifications 45 10 1 Ambient conditions 45 10 2 Interfaces 45 10...

Page 7: ...Raster Scan ORS technology 1 2 Model versions Mira P instruments are available in the following versions Table 1 Model versions 2 927 0010 Mira P Basic 1 927 0010 With Calibrate Verify Attachment CVA...

Page 8: ...manual Symbols and conventions The following icons and formatting may appear in this documentation Cross reference to figure legend The first number refers to the figure number the sec ond to the pro...

Page 9: ...actors such as system configuration cus tomer data and operator control Since implementation by customers of the equipment may vary the suitability of specific equipment configura tions and applicatio...

Page 10: ...d on the Internet You can download this information using the article number as follows Downloading the accessories list 1 Enter https www metrohm com into your Internet browser 2 Enter the article nu...

Page 11: ...arning messages indicate the severity of the danger and its possible effects DANGER Immediate danger of life Irreversible injuries that will result in death Warns of dangerous situations or unsafe act...

Page 12: ...take proper safety precautions when working with chemicals Adherence to this technical documentation and compliance with the maintenance specifications make up an important part of intended use Any u...

Page 13: ...t in Disturbing injuring and or killing of people Malfunction and or damage to instruments and infrastructure Damage and or contamination of the environment WARNING General dangers at workplace If the...

Page 14: ...that moisture has gotten into the instrument dis connect the instrument from the energy supply Then notify Met rohm Service Only personnel who have been issued Metrohm qualification may perform servi...

Page 15: ...of laser products and the regulations for the use of laser systems in your country Laser classification depending on smart tips Attached smart tip Laser Class 1 Laser Class 3B Right Angle Attachment X...

Page 16: ...stickers that warn of potential hazards These warning stickers are listed and explained below 1 Laser aperture 2 Laser aperture sticker 3 Laser specification serial number bot tom of instrument 4 Las...

Page 17: ...only valid ones Comply with the applicable statutory rules government agency directives and regulations Unauthorized modification of the products excludes any and all liability on the part of the man...

Page 18: ...authorized by the safety responsible to carry out the necessary operations They are capable of recognizing and avoiding possible dangers These people are qualified due to their profes sional training...

Page 19: ...ew of the instrument 13 3 Overview of the instrument Front Figure 4 Mira P Front 1 Magnetic smart tip fixture laser aper ture 2 Touch screen 3 Battery compartment 4 Type B mini USB connector 5 On off...

Page 20: ...Mira P Rear 1 Barcode reader 2 Accessories covering 3 Long Working Distance Attachment Lens LWD Storage 4 Short Working Distance Attachment Lens SWD Storage Case The instrument and attachments are de...

Page 21: ...3 Universal Attachment 4 Extra Long Working Distance Attach ment XLWD 5 Extra Long Working Distance Attach ment XLWD 6 Calibrate Verify Attachment CVA 7 Contact Ball Probe 8 Calibration Standard 9 Mi...

Page 22: ...16 NOTICE The following attachments are optional Contact Ball Probe Right Angle Attachment Tablet Holder XLWD...

Page 23: ...the delivery note to ensure completeness and absence of damage 4 2 Storing the packaging The product is supplied in extremely protective packaging together with the separately packed accessories Keep...

Page 24: ...teries of type AA LR6 NOTICE Battery type We recommend to use AA Energizer Ultimate Lithium batteries We also support rechargeable NiMH Panasonic eneloop pro batter ies NOTICE Power save mode If you u...

Page 25: ...Installation 19 Push the lateral cover upwards Open the lateral cover Open the top cover The battery compartment is now open...

Page 26: ...Power supply with batteries 20 Close the battery compartment Rotate the lateral cover Push the lateral cover down to the limit...

Page 27: ...you can operate the instrument with the USB interface which is connected to a powered USB hub The USB hub also allows data transfer NOTICE Battery charging function The instrument has no charging fun...

Page 28: ...USB connection 22 Refer to the Mira Cal P software tutorial for further steps Additional infor mation Software tutorials see chapter 1 5 page 4...

Page 29: ...ration NOTICE Configuration Use Mira Cal P software to change instrument settings or to install spectral libraries Refer to Mira Cal P software tutorial for detailed information Addi tional informatio...

Page 30: ...nstrument can identify them Due to design smart tips will not allow operation of Mira P when seated in an incorrect position The following attachments are within scope of delivery of Mira P Advanced C...

Page 31: ...be is 400 microns from the tip of the lens This means the probe will not perform well on substances through a bag The probe is designed for direct contact of liquids and solids Sleeves are available t...

Page 32: ...lass 3B laser operation The focal point is approximately 8 mm from the top of the lens The LWD attachment lens is used for sam ples in moderately thick walled bottles 6 Extra Long Working Distance Att...

Page 33: ...ed rooms only The protective glasses provided must be used when working with open laser beams e g attachment lens Observe the nominal ocular hazard distance NOHD Follow the provisions of the IEC 60825...

Page 34: ...Attaching smart tips 28 Side 1 of the CVA contains a toluene acetoni trile standard for calibration Side 2 of the CVA contains a polystyrene sam ple for verification...

Page 35: ...e used in protected and labeled rooms only The protective glasses provided must be used when working with open laser beams e g attachment lens Observe the nominal ocular hazard distance NOHD Follow th...

Page 36: ...ser radiation from emerging The lid contains a safety feature which cancels the measurement and stops the laser if you open the lid Attach the smart tip by engaging the bottom left corner of the tip i...

Page 37: ...nstructions Instruments must be used by trained personnel only Instruments of the laser class 3B must be used in protected and labeled rooms only The protective glasses provided must be used when work...

Page 38: ...Attaching smart tips 32 Attach the smart tip by engaging the bottom left corner of the tip into the left edge of the mounting point Rotate the tip into position...

Page 39: ...the laser class 3B must be used in protected and labeled rooms only The protective glasses provided must be used when working with open laser beams e g attachment lens Observe the nominal ocular hazar...

Page 40: ...et Holder Closing the lid prevents laser radiation from emerging The lid contains a safety feature which cancels the measurement and stops the laser if you open the lid Attach the smart tip by engagin...

Page 41: ...uired with the instru ment NOTICE Operating procedures and users have to be defined and synchronized beforehand in Mira Cal P Refer to Mira Cal P software tutorial for more information Additional info...

Page 42: ...n Login 3 Attach smart tip If not already done attach the correct smart tip to the instrument Attaching smart tips see chapter 7 2 page 27 Within an operating procedure a certain smart tip type may be...

Page 43: ...ck on to use the barcode reader instead of typing in by hand Barcode functionality and behavior is defined in the operating proce dure Click on Next 6 Enter Batch ID Lot ID Container Enter the Batch I...

Page 44: ...e next sample Click on Next to start the next measurement 7 4 Calibrate an instrument Calibration 1 Attach the CVA 2 Click on the instrument settings icon 3 Click on Calibrate Instrument 4 Click on Ca...

Page 45: ...wered instruments For an instrument connected with a power supply the shutdown delay is disabled By default no shutdown delay is configured Define a shutdown time to conserve battery charge For exampl...

Page 46: ...ium NiMH The change will be reflected by the text in the battery indicator This setting is persistent NOTICE We recommend to change the batteries when the battery indicator changes color from white to...

Page 47: ...or acetone Metrohm Service offers every form of technical advice for maintenance and service of all Metrohm products 8 2 Checking and replacing product parts To guarantee the flawless functioning and...

Page 48: ...sonnel who have been issued Metrohm qualification may perform service and repair work on electrical and electronic com ponents 8 3 Cleaning the product WARNING Danger of poisoning and chemical burns f...

Page 49: ...ohm Service Only personnel who have been issued Metrohm qualification may perform service and repair work on electrical and electronic com ponents Cleaning the surfaces of the product Prerequisites Th...

Page 50: ...lectronic Equipment The correct disposal of your old product will help to prevent negative effects on the environment and public health More details about the disposal of your old product can be obtai...

Page 51: ...nterfaces USB connector Type A B mini USB connector USB 2 0 with the following functions Power supply Data transmission with USB cable 6 2151 110 10 3 Power Supply Battery Battery specifications 2 x 1...

Page 52: ...ensions and materials Dimensions Width 88 4 mm Depth 44 8 mm Height 126 mm Display 3 7 TFT LCD Display glove compatible Weight 705 g Material Housing Aluminum anodized Accessories covering Thermoplast...

Page 53: ...WHM Collection optics NA 0 50 1 mm and 7 6 mm working distance 0 042 2 5 mm measuring spot size Beam divergence 2 degrees Detection technique Orbital Raster Scan ORS to average over the sample Laser c...