ANALYSING PERFORMANCE
45
76-02-011F
7 . 5. 4 Summary display - COUNTS style
Figure 7. 10 Performance summary screen - COUNTS style
Notes:
a) The display above is for G.751 Framed mode. In Unframed mode, only LOS and AIS (if
enabled) will show as alarms, and Code Errors will be the only Errors displayed.
b) If an alarm appears in Counts style, it appears only once as a single event, and is recorded
in the Temporary Counts column only. It may be best to confirm an alarm situation by setting
the summary screen to G.821 style when an alarm is present.
Metrodata FM4900: Local connection to
"[nodename]"
13:32:54 Tue3/4/2001 PERFORMANCE SUMMARY NI
Current Alarms: None ------------------------------------------------ Diag: None
Temporary
Current
Previous
Last
Counts
15 mins
15 mins
24 hours
Alarm counts
Total Secs
856
510
900
86400
LOS
0
0
0
0
LOF
0
0
0
0
AIS
0
0
0
0
RAI
0
0
0
0
SQ
0
0
0
0
FAS Errors:
0
0
0
0
Total secs
856
510
900
86400
Err Count
0
0
0
0
Error rate
0
0
0
0
<Escape> - exit, N - next interface, C - clear temp, other key - refresh