CONFIGURING THE FM4900
76-02-011F
30
When
FRAMED
mode has been selected and
DATALINK
has been set to
ON,
a
REMOTE
LOGON
option appears on the
MAIN SET-UP
menu. When you select
REMOTE LOGON
,
the local FM4900 Telnets across the datalink to the far end unit and allows you to logon to
the remote unit directly.
Note: This assumes that the remote unit’s datalink facility has also been enabled, and the
password is known.
When the datalink is in use the display will show as one of those below depending on which
of the two units is selected:
either
or
Figure 6. 13 Datalink screens
We advise that each unit be given a unique node name to make identification easier. To
logout of the remote unit and return to the local unit: press
<CTRL>
and
<]>.
6 . 4. 5 AIS Detection
This option will only appear on the menu when the mode is set to
UNFRAMED.
It allows
AIS
DETECTION
to be
ENABLED
or
DISABLED
. The AIS detector should always remain
enabled under normal datacomms conditions, and should only be disabled when there is a
very low zero density in the traffic.
Metrodata FM4900 : Local connection to "
[nodename]
"
Metrodata FM4900 : Remote connection to "
[nodename]
"