3.  Your C5 9 Series cabinet is capable of creating high levels of humidity at all operating temperatures. As you 

operate the cabinet and open and close the door(s), condensation will form on the inside surfaces of the cabinet. 

Some dripping of water may occur to the outside of the cabinet particularly at the door seals. A drip trough is 

part of the bumper and will direct most of this water to a removable water pan under the bumper. Water may also 

drip off opened doors onto the floor.

 Caution:

 

Water dripping onto the floor from open doors can be a slip hazard.

 Warning: 

Some surfaces, water and escaping vapor can be hot enough to burn. Use caution when opening doors 

and working in and around this cabinet.

4.  The cabinet controls will “remember” their settings when the cabinet is turned off. Therefore, when the unit is 

turned on the settings will be the same as they were during the previous use.

5.  A red indicator light below each digital display indicates when the temperature or humidity heater element is 

energized. As the control settings are adjusted, it may take a few moments for the status of the indicator lights 

to reflect the new control settings and cabinet conditions depending on when in the control cycle the settings 

are changed.

6.  If humidity is required, fill the water reservoir in the bottom of the cabinet to about 

1

/

2

" (13mm) below the bottom of 

the water reservoir cover. Potable (suitable for drinking) water should be used. Water can be poured through the 

rectangular hole in the water reservoir cover. If the cover is removed, replace it before using the cabinet. A water 

sensor detects a low water condition and will prevent the water reservoir element from being energized. The 

reservoir needs refilling when there is about 1" (25mm) of water left in the reservoir. At this point, the display will 

blink “Fill,” and an audible alarm will sound every 10 seconds, and 

the water reservoir element will not heat 

until the water reservoir is filled.

 If humidity is not required, empty the water reservoir and turn the humidity 

control knob counterclockwise until the display reads “Off.” This will prevent the display from blinking “Fill.”

7.  To remove the water from the water reservoir, allow the water to cool, open the drain valve under the right end of 

the drip trough and allow the water to drain. Any remaining water in the bottom of the reservoir can be removed 

with a clean towel.

 Note: 

When turning the cabinet off at the end of the work day, it is recommended to leave the door(s) open to 

prevent heat and condensation build up within the cabinet. 

 Note: 

If the cabinet is not going to be used for an extended period of time, all water should be removed from the 

water reservoir and the cabinet completely cleaned and dried out.

Water Reservoir Drain Valve

Water Reservoir 

Fill with water to one half inch 

below the water reservoir cover.

Element Indicators

Summary of Contents for C5 U-SERIES

Page 1: ...abinets with electrical ratings of 120V 2000W 120V 1440W 220 240V 1681 2000W When ordering electrical parts always confirm the rating listed on rear cabinet data plate Differences on voltage amps or wattage are listed with bold text in replacement part descriptions InterMetro Industries Corporation Wilkes Barre PA 18705 1 800 992 1776 www metro com L01 419 Rev I 10 11 17 ...

Page 2: ...ll continue to blink until the temperature set point is reached 7 To change temperature or humidity set points turn a control knob As a knob is turned the temperature and humidity display will show the set points and the F and C indicator lamps will blink About 3 seconds after a knob is turned the display will show the actual cabinet temperature and humidity 8 Press and release Recall Set Points b...

Page 3: ...se a food probe to check internal food temperature the cabinet temperature is not necessarily the internal food temperature WARNING Only factory approved service agents should attempt to service repair or replace electrical components wiring or power cord WARNING Unplug the cabinet before cleaning or servicing Do not wash the cabinet with a water jet or high pressure water WARNING This cabinet is ...

Page 4: ...TYPE 9 9 SERIES CONTROLLED HUMIDITY CABINET SIZE HEIGHT 9 FULL 7 3 4 5 1 2 3 UNDER COUNTER MATERIAL S STAINLESS N ALUMINUM A ACCESSORIES IF APPLICABLE ELECTRICAL CABINET RATING BLANK 120V 2000W L 120V 1440W X 220 240V 50 60HZ 1681 2000W REAR DOOR S PASS THRU BLANK NON PASS THRU FS FULL SOLID DS DUTCH SOLID FC FULL CLEAR DC DUTCH CLEAR CABINET CONSTRUCTION BLANK NON PASS THRU P PASS THRU DOORS FRON...

Page 5: ... ground wire connection and the wire nuts on the black and white wires have not loosened Do not alter the wiring of the power cord to the cabinet Replace the cabinet top and the 7 screws holding it in place 7 Refer to the data plate located near the power cord for the electrical specifications of cabinet With the POWER switch OFF plug the cord into the appropriate rated grounded receptacle Cabinet...

Page 6: ... uprights includes slides and uprights includes slides and uprights SLIDE INSTALLATION The rack uprights have been installed at the factory If removed for cleaning reinstall by hanging them on the shoulder rivets on the side walls of the cabinet INSTALLATION AND SET UP continued SiteSelect features make slide installation easier Slides sold in pairs For additional pair of wire slides order C5 USLI...

Page 7: ...er Counter Single Door Dutch Doors Cabinet Cabinet Cabinet 2 piece Construction 2 piece Construction 1 piece Construction 1 piece Construction 1 piece Construction Part No RPC5 L9 Part No RPC5 L9 Part No RPC5 L7 Part No RPC5 L5 Part No RPC5 L3 INSTALLATION AND SET UP continued Slides sold in pairs ...

Page 8: ...ow the top and install the hinges On Dutch Doors do not remove the handles the top door becomes the bottom and the bottom door the top On single door units rotate the handles 180 and reinstall 4 On the cabinet mounted hinges lift the white bushing and rotate it 180 and push it down to reseat it on the hinge pin 5 Install the door onto the cabinet hinges and check to make sure the door latches prop...

Page 9: ...l Displays cabinet s temperature and humidity set points Temperature Scale Indicators Set to Fahrenheit in the factory These indicators will also blink while the temperature and humidity set points are being displayed Air Temperature Display Displays the current cabinet temperature Also displays low temperature warning Audio Disable Sound Off Press Recall and Low Temp Alarm buttons simultaneously ...

Page 10: ...oint However this will rapidly correct itself and equalize to the operating temperature within a few minutes The C5 controls will continuously monitor temperature and humidity and energize the heat elements accordingly Note as the cabinet pre heats the air the humidity level may drop significantly This is because hotter air can hold more moisture and therefore the relative humidity goes down as th...

Page 11: ...about 1 2 13mm below the bottom of the water reservoir cover Potable suitable for drinking water should be used Water can be poured through the rectangular hole in the water reservoir cover If the cover is removed replace it before using the cabinet A water sensor detects a low water condition and will prevent the water reservoir element from being energized The reservoir needs refilling when ther...

Page 12: ...ts the water to create humidity and a water level sensor As water evaporates from the reservoir any minerals and chemicals present in the water are left behind in the remaining water Given enough time these minerals can build up on the reservoir heater and sensor causing corrosion and a decrease in performance Using distilled water or conditioned water will help prevent scale build up If distilled...

Page 13: ... may occur but will quickly return to the set point c If displayed temperature exceeds 220 F 104 C i Blower wiring is faulty or disconnected ii Blower needs replacing iii The thermostat may have failed and the thermal overload device is controlling the temperature Stop using the cabinet immediately and contact a factory approved service agent d Water reservoir may be empty but the water reservoir ...

Page 14: ...O or Fill and Alarm beeps if Sound is on a If the temperature display alternately blinks the current cabinet temperature and then LO refer to steps 5 and 6 b If the humidity display alternatively blinks the current cabinet humidity level and Fill refer to steps 8d and 8e 11 Water level is low but display does not flash Fill a Accumulation of dirt or scale needs to be cleaned off of water level sen...

Page 15: ...3 348 POWER CORD 15A RT ANGLE PLUG RPC13 289 POWER CORD 15A STR PLUG RPC13 337 POWER CORD 15A TWIST LK PLUG 9 RPC5 RTWSTPLG POWER CORD 20A CORD 9A RPC13 083 STRAIN RELIEF 15A CORD 10 RPC13 096 TERMINAL BLOCK 11 RPC07 055 SENSOR CABLE GROMMET 12 RPC5 SCLP SENSOR CLAMP SCREW 13 RPC5 WSNSR WATER SENSOR FLGD BUSHING 14 RPC06 885 FLGD BUSHING WATER SENSOR 15 RPC15 030 BULKHEAD FITTING 16 RPC13 200 WATE...

Page 16: ...1 PIECE 21 RPC5 9 BMPR BUMPER DRIP TROUGH 22 B5DNB 5 BRAKE CASTER B3B 3 BRAKE CASTER RPQC02 248 6 BRAKE CASTER B5DNR 5 RIGID CASTER ITEM Replacement Part No Description 23 B5DN 5 SWIVEL CASTER B3 3 SWIVEL CASTER RPQC02 247 6 SWIVEL CASTER B5DNR 5 RIGID CASTER 24 RPC5 DRPAN DRAIN PAN 25 RPC06 872 POCKET HANDLE 26 RPC15 028 RESERVOIR DRAIN VALVE 27 RPC5 9 WRSVR WATER RESERVOIR GASKET 28 RPC06 881A W...

Page 17: ... 8A 8 25 31 32 19 21 23 34 18 33 24 22 21 36 30 17 10 11 WATER RESERVOIR See page 16 WIRE COVER CABINET BODY AIR DUCT See page 13 CONTROL PANEL See page 15 RESERVOIR COVER or or 37 40 3 5 or 6 3 5 or 6 20 41 For slide identification see pages 4 and 5 STRAIGHT PLUG CORD SHOWN ...

Page 18: ... 35 INSULATION ENCLOSURE For Selected Models Only For Selected Models Only SERVICE and REPLACEMENT PARTS continued WATER RESERVOIR Warning Only factory approved service agents should attempt to service repair or replace electrical components wiring or power cord ...

Page 19: ...TE X 18 BLACK X 15 SPADE TO STRIPPED END STRAIN RELIEF GREEN WHITE BLACK SERIAL 20A RIGHT ANGLE PLUG POWER CORD SHOWN BLOWER T O D AIR HEAT ELEMENT WATER PAN ELEMENT WATER PROBE CONTROLLER J17 J18 J6 J5 J7 J4 J9 J15 19 9 21 10 11 18 6 11 10 6 A A 23 4 3 2 1 1 2 RIBBON CABLE TO TOUCH PAD FUSE AIR FLOW 3 18 GA BLACK X 14 18 GA BLACK X 14 FAN 15 6 3 12 9 10 11 19 20 18 24 15 21 22 23 19 22 23 24 3 9 ...

Page 20: ...18 InterMetro Industries Corporation hereinafter referred to as Seller warrants to the 10 17 ...

Page 21: ...customer information space below Thank You FOLD HERE DO NOT DETACH CUSTOMER INFORMATION 1 Which one of the following best describes your establishment a Full Service Restaurant b Banquet Hall c Hotel Motel d Hospital Nursing Home e College University f School g Employee Feeding h Other 2 Please indicate the two product benefits that were of major interest to you a Easy to use controls b Humidity r...

Page 22: ... WILL BE PAID BY INTERMETRO INDUSTRIES CORPORATION ATTN CUSTOMER SERVICE P O BOX A WILKES BARRE PA 18705 9968 STAPLE HERE BUSINESS REPLY MAIL F I R S T C L A S S P E R M I T N O 1 2 1 W I L K E S B A R R E PA NO POSTAGE NECESSARY IF MAILED IN THE UNITED STATES ...

Page 23: ...THIS PAGE IS KEPT INTENTIONALLY BLANK ...

Page 24: ...th Washington Street Wilkes Barre PA 18705 For Product Information Call 1 800 992 1776 Visit Our Web Site www metro com L01 419 Rev I 10 17 Information and specifications are subject to change without notice Please confirm at time of order ...

Reviews: