Functional Description
IV - 50
Function/Arbitrary Waveform Generators
Functional Description (contd.)
To Set the DC
Output
Press Utility
→
DC
→
On , to enter the following interface. Please note that
there is a “Direct Current On” sign at the middle left of the screen.
DC Setting Interface
DC Offset
Set the DC voltage level.
To Shift into the
Arbitrary
Waveform Output
1. Press Utility
→
DC
→
DC Off, to close DC output and return to arbitrary
waveform output.
2. Press any functional button, and the waveform output setting turns into
the arbitrary waveform output. The DC option is turned off automatically.
To copy the
settings
Press Utility
→
Copy
→
On, to copy the settings to the other’s channel.
To Set Output
Parameter
Press Utility
→
Output Setup, to enter the following interface.