MD 9040 & MD 9050 Digital multimeter
Specification
20
Other function ranges:
Total Accuracy = Specified Ac 100 digits
Performance above 3V/m is not specified
Power Supply:
Single 9V battery; NEDA1604G, JIS006P IEC6F22,
NEDA1604A, JIS6AM6 or IEC6LF22
Power Consumption:
5 mA typical
APO Timing:
Idle for 30 minutes
APO Consumption:
50
A typical
Dimension:
L208mm X W103mm X H64.5mm with holster
Weight:
635 gm with holster
Accessories:
Test lead pair; battery installed; user’s manual; AMD9023
banana plug type-K thermocouple (MD 9050)
Optional purchase accessories:
USB interface kit AMD9050; AMD9024 banana plug to type-
K socket plug adaptor
Electrical Specifications
Accuracy is
(% reading number of digits) or
otherwise specified, at 23
o
C
5
o
C & less than 75% relative
humidity.
True RMS voltage & current accuracies are specified from 10 % to 100 % of range or otherwise
specified. Maximum Crest Factor < 3:1 at full scale & < 6:1 at half scale, and with frequency
components within the specified frequency bandwidth for non-sinusoidal waveforms.