MI 3109 EurotestPV Lite
Measurements
45
See chapter 4.2 Function selection for instructions on
key functionality.
Figure 5.
30
: Environmental
parameters screen
Test parameters for measuring / setting of environmental parameters
INPUT
Input of environmental data [ MEAS, MANUAL]
OTHER
Shortcut to SOLAR SETTINGS menu
Connection for measuring of environmental parameters
Figure 5.31: Measurement of environmental parameters
Procedure for measuring of environmental parameters
Select
ENV.
function and
MEAS
sub-function using the function selector keys
and
/
keys.
Connect
environmental probes to the instrument (see
Connect
probes to the item to be tested (see
Press the
TEST
key to perform the measurement.
Store
the result by pressing the
MEM
key (optional).
Figure 5.32: Example of measured results
Displayed results for environmental parameters:
Irr………………...solar irradiance
Tamb or Tcell…. temperature of ambient or PV cells
Note
:
If the Irradiance result is lower than the set minimal value Irr min the STC results
will not be calculated (message
is displayed).
Procedure for manual entering of environmental parameters