9 Technical specifications
9.1 Voltage, frequency, and phase rotation
9.1.1 Voltage
Measuring range (V)
Resolution (V)
Accuracy
0
550
1
(2 % of r 2 digits)
Result type ........................................ True r.m.s. (trms)
Nominal frequency range .................. 0 Hz, 14 Hz
500 Hz
9.1.2 Frequency
Measuring range (Hz)
Resolution (Hz)
Accuracy
0.00
9.99
0.01
(0.2 % of r 1 digit)
10.0
499.9
0.1
Nominal voltage range ...................... 10 V
550 V
9.1.3 Online terminal voltage monitor
Measuring range (V)
Resolution (V)
Accuracy
10
550
1
(2 % of r 2 digits)
9.1.4 Phase rotation
Nominal system voltage range ......... 100 V
AC
550 V
AC
Nominal frequency range .................. 14 Hz
500 Hz
Result displayed ............................... 1.2.3 or 3.2.1