A 1472, A1579 Leakage current clamp
22
5
Technical specifications
List of instruments that support operation with A 1472
Current clamp is designed to be used in combination with following
METREL testers:
PAT tester DeltaPAT BT MI 3309
PAT tester DeltaGT BT MI 3309
List of instruments that support operation with A 1579
PAT tester OmegaPAT MI 3360
Rated current: see the table bellow
Current ratio : 1000:1
Output:1 mA/A,
Output terminals: safety banana sockets
4 mm, Guard terminal
Electrical characteristics
Measuring range: 0.5 mA
÷ 10 A
Accuracy:
5%
Frequency range: 40 Hz
÷ 5 kHz
Max. input current: 100 A
Safety specification
Type A (application around and removal form hazardous live conductors is
permitted)
Over voltage category: 300 V CAT III/ 600V CAT II
Pollution degree: 2
Double insulation
Environment conditions
Working temperature: 0
C
÷ 60
C
Storage temperature: -20
C
÷ 70
C
Humidity: 0 %
÷ 85 %, linearly decreasing for T > 35
C
Altitude: working 0 to 2000 m
Mechanical data
Jaw opening: 40 mm
Dimension: 177 mm x 53 mm x 23 mm
Weight: ~160 g
Applied standards
Safety: EN/IEC 61010-1
EN/IEC 61010-2-32