 Connections 

 
 

 

 
 
 

description 

  # 

description 

BDM Loader 

 

3  Power and Metra NET Network 

External Reader/Barcode Scanner 

 

   

 
 

 Power and Metra NET Network connection 

 

 WARNING 

 

 

Mind  the  power  and  Metra  NET  Network  polarity!  Wrong  polarity  could  result  in  irreparable 
damage to the device.  

 

Respect power requirements data! Using unsuitable power supply could result in damage to the 
power supply and to the device. 

 
Regulated DC power supply is required for proper operation. Connect as many units as possible to a 
single power supply unit. See chapter 

“Technical data”

 for power requirements.  

 
The  Metra  NET  Network  connection  provides  for  operational  functionality  of  the  Reader  Terminal 
Combo. 

 
 

 

Tools required:

 Small flathead screwdriver 

 

 
 

Summary of Contents for RTKP

Page 1: ...Reader Terminal Keypad Technical Manual...

Page 2: ...anual Table of contents Reader Terminal Combo User Manual 3 Product description 3 Connections 4 Power and Metra NET Network connection 4 DIP switch settings 6 Network address 7 Operating indicator 8 M...

Page 3: ...e All efforts have been made to ensure the accuracy of the contents of this manual however should any errors be detected Metra in eniring would greatly appreciate being informed of them Metra in eniri...

Page 4: ...lt in irreparable damage to the device Respect power requirements data Using unsuitable power supply could result in damage to the power supply and to the device Regulated DC power supply is required...

Page 5: ...ched and therefore you can skip step 1 STEP 1 Insert wires from the 12V DC regulated power supply and Metra NET Network cable into the connector and fasten them with screws STEP 2 Attach the connector...

Page 6: ...tions use a small flat headed screwdriver or similar object to push DIP switch pins to desired position After each address change or after device s first installation power off and back on the device...

Page 7: ...0 0 1 1 0 170 0 0 0 0 1 1 1 107 1 0 0 0 1 1 1 171 0 0 0 1 0 0 0 108 1 0 0 1 0 0 0 172 0 0 0 1 0 0 1 109 1 0 0 1 0 0 1 173 0 0 0 1 0 1 0 110 1 0 0 1 0 1 0 174 0 0 0 1 0 1 1 111 1 0 0 1 0 1 1 175 0 0 0...

Page 8: ...150 1 1 1 0 0 1 0 214 0 1 1 0 0 1 1 151 1 1 1 0 0 1 1 215 0 1 1 0 1 0 0 152 1 1 1 0 1 0 0 216 0 1 1 0 1 0 1 153 1 1 1 0 1 0 1 217 0 1 1 0 1 1 0 154 1 1 1 0 1 1 0 218 0 1 1 0 1 1 1 155 1 1 1 0 1 1 1 2...

Page 9: ...ed Current consumption 0 50 A Operating temperature range 10 to 50 C Audio signal integrated piezoelectric beeper Visual signalization 4 digit LED display with decimal points Connectors Power Metra NE...

Page 10: ...a special dummy drill mask is available to facilitate the drilling procedure Appendix 1 Reader Terminal Keypad Physical dimensions Reader Terminal mounting hole min 100 min 300 214 208 4 73 79 120 233...

Page 11: ...Round hole must be provided for mounting the Barcode Scanner Appendix 2 Barcode Scanner Physical dimensions Barcode Scanner mounting hole min 120 min 100 79 73 4 73 79 78 6 110 72...

Page 12: ...Appendix 3 Inner connections schematic 1 2 5 3 4 8 7 6 Schematic shows Barcode Scanner...