Locker Controller ELS ASSIGN Touch Technical Manual
Metra NET Network connection (Locker Controller without distribution board)
The Metra NET Network connection provides for operational functionality of the Locker Controller.
Different devices in parallel can be connected to the Metra Network Controller by a single unshielded
twisted pair (UTP) cable. Total length of the twisted pair cable is limited to 1 km. One Network Line
Terminator must be connected at the far end of the network cable. See also
“Metra NET Network –
Installation Manual”
for different wiring schemes.
Connect the twisted pair network cable to designated terminals. The terminals are marked as
CANLO
for network low signal and
CANHI
for network high signal.
NOTE
Mind the polarity of the network connection!
Metra NET Network connection (Locker Controller with distribution board)
Connect the twisted pair network cable to designated terminals. The terminals are marked as
CANL
for network low signal and
CANH
for network high signal.
NOTE
Mind the polarity of the network connection!