17.3.2005
Rev. 2.0
Adjustment instructions
26
6.8
Calibration of control panel
Place the bowl in the bowl arms and raise the bowl to top position.
Activate the emergency stop to switch off the power to the mixer.
Release the emergency stop to connect the power to the mixer.
Within 3 seconds activate the field “speed down” and “start/stop” simultaneously.
The text field will now show
Activate the fields “1”,”2”, “3” and “4”.
The text field will now show
Activate the fields “time down” and “time up” simultaneously.
The mixer will automatically calibrate the control panel.
is shown in the text field for calibration of minimum speed.
is shown in the text field for calibration of maximum speed.
is shown in the text field for completion of calibration.
After 3 seconds the sequence will be completed automatically.
Switch off the power to the mixer this can be done via the emergency stop.
The mixer is ready for use.