5
TEROS 12
Table 1 Installation (continued)
Installation
(continued)
Secure and Protect Cables
Secure and protect cables with PVC casing or flexible conduit to protect
against damage from rodents or driving over sensor cables.
Secure Excess Cable
To prevent loose cabling from being inadvertently snagged or tripped over,
gather and secure excess cable to the mounting mast in one or more places.
Tie excess vertical cable to the data logger mast to ensure cable weight does
not cause sensor to unplug.
Relieve Cable Strain
To relieve strain on the connections, leave the cables a little loose between the
logger and the closest secured point on the mast. This will allow for thermal
expansion and contraction of the cable without potentially pulling the stereo
connection out of the logger.
ERROR
OK
TEST
(–)
(+)
(–)
(+)
(–)
(+)
(+)
(–)
(+)
(–)
P1
P2
P3
P4
P5
P6
Securing excess cable
contains brief descriptions for typical installation methods. Each has its own
advantages and disadvantages. For more information about which installation method
is best for specific applications, please see the
TEROS 12 Installation Guide
or contact
.