OPERATIONS 4-28
MCC-545C PACKET DATA RADIO
12/2000
MCC-545C COMMANDS
COMMAND
DESCRIPTION
PARAMETERS
RANGE
*DEVICE
{,type}
Select device type mode of operation (i.e., the MCC-
545C acts as a Remote or a limited Master Station).
type =
REMOTE
MASTER
DQERXQ
,nnnn:sss
Delete specified message from the receive queue
nnnn=Station ID
Master =
1 – 245
Remote =
256 –
4095
sss = msg serial
number
1 – 4095
1 – 245
DQETXQ
,nnnn:sss
Delete specified message from the transmit queue
nnnn=Station ID
Master =
1 – 245
Remote =
256 –
4095
sss = msg serial
number
1 – 4095
1 – 245
*DUTY CYCLE
{,percent}
Set transmitter duty cycle (default is 10%). Duty cycle
increases in increments of 5%.
percent =
1 – 100
1 – 100
FLASH
Initiate flash memory download. You must type a dozen
or so “f” characters after entering the command to cause
the bootstrap to take control and initiate the download
dialog.
†FLOOD TIMEOUT
{,t}
Display/set timeout period in minutes for the time after a
flood that the Stations are to report once a minute
t = timeout in
minutes
1 – 1440
FLUSH MSG
Delete all messages from all queues.
FLUSH RXQ
,nnnn
Delete all elements of specified Station from receive
queue.
nnnn = Station ID
Master =
1 – 245
Remote =
256 –
4095
1 – 4095
Summary of Contents for MCC-545C
Page 1: ...FCC ID BIB5450500101 EXHIBIT VIII OPERATION AND MAINTENANCE OF THE MCC 545C PACKET DATA RADIO...
Page 9: ...DESCRIPTION 2 4 O M of the MCC 545C PACKET DATA RADIO 12 2000...
Page 12: ...DESCRIPTION 2 7 O M of the MCC 545C PACKET DATA RADIO 12 2000...
Page 22: ...DESCRIPTION 2 17 MCC 545C PACKET DATA RADIO 12 2000...
Page 36: ...DESCRIPTION 2 31 MCC 545C PACKET DATA RADIO 12 2000...