![Metek Powervar Security II Series Manual Download Page 52](http://html.mh-extra.com/html/metek/powervar-security-ii-series/powervar-security-ii-series_manual_1777549052.webp)
52
A01-00055 Rev M
International Models ABCE1102-22 and ABCE1102-22MED
ABCE1102-22
51110-03R
ABCE1102-22MED
51110-23R
Type
Standard
Medical Grade
Power Rating (VA/Watts)
1100 / 990
1100 / 990
Inverter Waveform
Low Distortion Sine Wave
Low Distortion Sine Wave
Transfer Time
4 ms. Typical
4 ms. Typical
Frequency
50 / 60 Hz.
50 / 60 Hz.
BTU/Hr.
239
239
T.H.D. w/100% Resistive Load
<4% on Battery
<4% on Battery
Online Efficiency (w/o Charger)
93%
93%
Input Voltage
230
230
Input Current
8.10 Amps
8.10 Amps
Output Voltage
230
230
Output Current (VA/Watts)
4.80 / 4.30 Amps
4.80 / 4.30 Amps
Input Voltage Range
(w/o Using Battery)
185 to 276 volts
185 to 276 volts
Output Regulation (Mains)
± 10%
± 10%
Output Regulation (On Battery)
± 5%
± 5%
Backup Time at Full Load (0.7 P.F.)
> 5 Minutes
> 5 Minutes
Floor Mountable
Yes (Optional)
Yes (Optional)
Communications Interface
DB9, USB (SNMP Optional)
DB9, USB (SNMP Optional)
Shipping Weight (kg)
32
32