Thermal Imaging Camera
Installation Guide
LWIR
5- 10
Output 2
For Output 2, the
mA Out
settings are identical in operation to those of
Output 1.
For the
Relay
settings, use the drop-down boxes to select the source of the
output e.g. ROI 1, and the type of output required e.g. Maximum temperature.
Use the text input field or the slider bars to set the upper and lower limits for
this setting
For example, for
ROI 1
you could set the
Maximum
Temperature
to activate
the relay output if it goes outside the range
600 °C
to
750 °C
.
You can specify multiple triggers for the relay by simply clicking on the
Add
button.
For a relay output with multiple triggers, if the
Alarm logic
control is set to
OR
, the relay is triggered when
at least one
of the alarm conditions is met.
If the
Alarm logic
control is set to
AND
, the relay is triggered when
all
of the
alarm conditions are met simultaneously.
For example, you can set the relay output to be activated if the
Maximum
Temperature
of
ROI 1
goes outside the range
600 °C
to
750 °C
, OR the
GLOBAL Maximum Temperature goes outside the range
400 °C
to
500 °C
To delete a relay setting, click on its
Remove
button
Summary of Contents for LAND LWIR
Page 47: ......