The new advanced EB 80 diagnostic functions, known as EB 80 I4.0, provide a powerful analysis tool for traditional maintenance operations,
ensuring the safe, reliable and lasting operation of production units.
Assignment of diagnosis addresses
N° byte EB80I4_0
Dimensions [byte]
System data
Counter switching
from Byte1_I2100_S32 to Byte4_I2100_S35
4
Power alarm counter
Byte5_I2100_S36
1
Reserved
Byte6_I2100_S37
1
Valve data
Valve ID (the ID of the pressure regulators is subsequent to the last valve installed)
Byte7_I2100_S38
1
Pressure Regulator
Byte8_I2100_S39
1
Pilot
1
Average life excess signal - bit 0
Byte9_I2100_S3A
1
Short-circuit alarm counter
Byte10_I2100_S3B
1
Circuit open alarm counter
Byte11_I2100_S3C
1
Cycle counter
from Byte12_I2100_S3D to Byte15_I2100_S40
4
Counter of total pilot 1 energising time [sec] - operating hour meter of pressure regulator from Byte16_I2100_S41 to Byte19_I2100_S44
4
Pilot
2
Average life excess signal - bit 0
Byte20_I2100_S45
1
Short-circuit alarm counter
Byte21_I2100_S46
1
Circuit open alarm counter
Byte22_I2100_S47
1
Cycle counter
from Byte23_I2100_S48 to Byte26_I2100_S4B
4
Counter of total pilot 2 energising time [sec]
from Byte27_I2100_S4C to Byte30_I2100_S4F
4
Actuator data
Actuator Id
Byte31_I2100_S50
1
State
Byte32_I2100_S51
1
Actuation delay [ms]
from Byte33_I2100_S52 to Byte34_I2100_S53
2
Reset delay [ms]
from Byte35_I2100_S54 to Byte36_I2100_S55
2
Actuation time [ms]
from Byte37_I2100_S56 to Byte40_I2100_S59
4
Return time [ms]
from Byte41_I2100_S5A to Byte44_I2100_S5D
4
Actuator stroke counter
from Byte45_I2100_S5E to Byte48_I2100_S61
4
Total
48
7. I4.0 FUNCTIONS
The new advanced EB 80 diagnostic functions, known as EB 80 I4.0, provide a powerful analysis tool for traditional maintenance operations,
ensuring the safe, reliable and lasting operation of production units.