63
5.6 DIGITAL OUTPUT
1 input byte is available (bit 0) for the pressure switch function of the Pressure Regulators.
5.6.1 PRESSURE SWITCH CONFIGURATION (P) - Digital Out I5FCx_S06 = 0
The activation of the Out occurs when the pressure set in P ON is reached.
The deactivation of the Out occurs when the pressure set in P OFF is reached.
Keyboard setting:
• Select
OUTPUT
using the arrow keys, then press OK.
• Select
CONFIGUR.
to select the operating mode, then press OK.
• Select
PRESSURE SWITCH
, then press OK.
PRESSURE SWITCH
mode,
shown with
CONFIGUR. P.
has been selected.
•
Use the arrow keys to select
PRESSURE SWITCH
and press OK.
• Select
P ON
and press OK. Enter the desired activation pressure and
press OK.
• Select
P OFF
and press OK. Enter the desired deactivation pressure
and press OK.
• Press ESC to exit the menu.
P ON = I5FCx_S07
P OFF = I5FCx_S08
The value is expressed in mbar.
5.4 DEBUG - The function is only available from the keyboard
Utility used for checking correct operation of the two solenoid valves.
• Select
DEBUG
and press OK.
• Select
PIN
and press OK. The in solenoid valve activates and the pressure
increases.
• Press OK. The in solenoid valve deactivates and pressure stabilizes.
• Select
POUT
and press OK. The out solenoid valve activates and pressure
decreases.
• Press OK, the out solenoid valve deactivates and pressure stabilizes.
5.5 PASSWORD - The function is only available from the keyboard
This is a three-digit code used to protect the set configuration.
• Select
SET PASSWORD
with the arrow keys and click OK. On the setting page, use the arrow keys to enter the desired value and click OK to
confirm. The system then displays the confirmation message “
PASSWORD SAVED
”.
• Select
PASSWORD
and click OK to enable/disable the function. If the password set to
ON
, it prevents access to the configuration menu.
When you press OK+ESC together to access the configuration menu, you are prompted to enter the password.
Enter the saved password. You can use the arrow keys to change the value or click OK to change the field.
If the password is set to
OFF
, it is not enabled.
If you forget the password, contact the manufacturer to obtain a password reset code.