26
3.3. DISPLAY
Is possible to rotate the display by 90°, 180° or 270° to adapt it to the mounting position, by pressing the two keys indicated
by the icon for
1 second
.
3.3.1 PARAMETERS
• Language: Italiano, English, Deutsch, Français, Español.
• Flow rate unit of measurement: Nl/min, Nl/h, Nm
3
/min, Nm
3
/h, Nft
3
/min, Nft
3
/h.
• Pressure unit of measurement: bar, MPa, psi.
Setting the flow rate value display for colour change from orange to yellow.
Can be used to highlight abnormal air consumption.
• SET FL COL. – flow rate value at which the colour changes to yellow.
• RES FL COL. – flow rate value at which the colour reverts to orange.
3.4 SERVICE
• Consumption reset
: accumulated consumption is reset.
• Sensor check
: with flow rate and pressure at zero, it verifies that the measuring sensor is not faulty.
• Internal temperature
: displays the temperature of control electronics.
• Factory reset
: resets the factory configuration.
3.5 INFO
• S/N
: serial number.
• Software version
.
• Diameter
: diameter of the internal passage.
• Pressure
: pressure transducer availability.
• Model
: type and options available.
A
Analogue
I
IO-Link
H
Display
4. MENU ACCESS FROM KEYPAD (ONLY FOR MODELS WITH DISPLAY)
• Press the
and
buttons simultaneously for
1 second
to access the parameter setting menu.
• Use the arrow keys
to scroll through the menu and edit the parameters.
• Press OK to confirm.
SETUP
PLANT
I/O
DISPLAY
SERVICE
INFO
ESC
OK
+