10
COOKING POT
3/8 FEMALE
FLARE SWIVEL
BURNER
ADJUSTABLE REGULATOR
TYPE 1 CONNECTION
N
O
HALF UNION
VENTURI TUBE
AIR
SHUTTER
COOKING POT
1/8 MALE PIPE THREAD
BURNER
NEEDLE VALVE
TYPE 1 CONNECTION
PRESSURE REGULATOR
NON-ADJUSTABLE
VENTURI TUBE
AIR SHUTTER
Figure 2
HOSE WITH FEMALE FITTING AND ADJUSTABLE REGULATOR.
Figure 3
HOSE WITH MALE OR FEMALE FITTING AND NEEDLE VALVE WITH
NON-ADJUSTABLE PRESSURE REGULATOR.
The air shutter and half union as pictured should already be assembled to the casting. Check that
fitting is tightened to the venturi tube and that the elbow points downward. Tighten the hose fitting
onto the half union with a torque wrench, up to a torque of 95 to 105 lb./in. Alternatively, hand
tighten securely and then, using a wrench, tighten an additional 1-1 1/2 turns.
If your cooker has a needle valve and a non-adjustable pressure regulator as above with a 1/8 male
pipe thread, refer to directions in Figure 1.
If your cooker has a needle valve and a non-adjustable pressure regulator as above, but a 3/8
female flare swivel, refer to the directions for Figure 2.
20 lb. LP
Gas Cylinder
20 lb. LP
Gas Cylinder
36825GAkk 3/29/06 9:49 AM Page 10