METAL-FACH
Heating Technology
10
Technical data of the boiler
(User | Installer)
Parameters
S.I. Unit.
Boiler model
SE MAX OPTI 20
SE MAX OPTI 30
SE MAX OPTI 40
Nominal heat output
[kW].
23
30
40
Heating surface
[m2]
2,8
3,5
4,1
Water capacity
[L]
97
120
170
Maximum operating pressure
[bar].
3
3
3
Maximum operating temperature
[°C]
80
80
80
Test pressure
[bar].
4,5
4,5
4,5
Boiler class
-
5
5
5
Boiler efficiency
[%]
≤90
≤90
≤90
Fuel
[-]
Firewood - hornbeam logs with moisture content of
Wc=15-20%
Circumference of logs
[cm].
30-40
Length of billets
[cm].
26
Electrical connection
-
1A; ~230V; 50Hz
Electrical power consumption
[W]
70
70
70
Electric power consumption
(instantaneous at start-up)
[W]
70
70
70
Setting range of temperature controller
[°C]
60-80 (in
1°C steps)
Required chimney draught
[Pa]
23
35
35
Design flow resistance ΔT [10K]
[mbar].
12,3
24,75
29,83
Design flow resistance ΔT [20K]
[mbar].
3,8
5,05
7,45
Boiler mass *
[kg].
414
477
569
Volume of heat storage tank (buffer)
[L]
900
1200
1600
* Boiler /- 5kg.