10
ENGLISH
After all servicing:
−
Check to see that all safety
devices are operational.
−
Make sure that no tools or other
parts remain on or in the
machine.
Compressor does not run:
•
No mains voltage.
−
Check cables, plug, outlet and
mains fuse.
•
Mains voltage too low.
−
Use only extension cables with
sufficient lead cross section (see
"Technical Specifications"). Avoid
using extension cable with cold
machine.
•
Compressor was stopped by
unplugging.
−
Switch compressor OFF at the
On/Off switch, then ON again.
•
Motor has overheated, caused by
insufficient cooling (cooling fins cov-
ered).
−
Remove cause for overheating
and allow to cool down for
approx. 10 minutes, then start
again.
Compressor runs but does not build
up sufficient pressure.
•
Check valve leaky.
−
Have check valve serviced by
qualified service centre.
Air tool is not supplied with sufficient
pressure.
•
Pressure regulator not opened wide
enough.
−
Open pressure regulator more.
•
Hose connection between compres-
sor and air tool leaky.
−
Check air hoses, replace defec-
tive parts if necessary.
A
Danger!
Repairs to power tools must be
carried out by qualified electricians
only!
Electric tools in need of repair can be
send to the service centre in your coun-
try. See spare parts list for address.
Please attach a description of the fault to
the power tool.
The machine's packaging can be 100 %
recycled.
Worn out machines and accessories
contain considerable amounts of valua-
ble raw and plastic materials, which can
be recycled.
These instructions are printed on chlo-
rine-free bleached paper.
7. Repairs
8. Environmental Protection
9. Technical Specifications
Basic 240
Basic 240 (GB 110V)
Suction capacity
l/min
220
220
Free air delivery (volume flow rate)
l/min
105
105
Filling rate
l/min
110
110
Working pressure (compression end pressure)
bar
8
8
Pressure vessel volume
l
24
24
Pump model
F 205
F 205
No. of cylinders
1
1
Motor speed
min
-1
2850
2750
Motor capacity
kW
1.1
1.35
Supply voltage (50 Hz)
V
230
110
Rated current
A
6.2
14.0
Fuse protection min.
A
10 (time-lag)
Degree of protection
IP 20
IP 20
Max. overall cable length when using extension cables:
– at 3 x 1.0 mm
2
lead cross section
– at 3 x 1.5 mm
2
lead cross section
– at 3 x 2.5 mm
2
lead cross section
m
m
m
10
25
50
Dimensions length x width x height
mm
615 x 325 x 630
615 x 325 x 630
Weight
kg
21.5
21.5
Sound pressure level at 1 m max.
dB (A)
85 ± 3
85 ± 3