The alarm central unit protects the motorcycle against being started and an alarm cycle will be
triggered every time:
• The ignition key is turned ON
• An attempt is made to remove or move any part of the motorcycle which is protected by
specifi c switches (for example if the seat or the storage compartment is opened...)
• The motorcycle is moved
• The alarm system’s supply cables are disconnected or cut or if the motorcycle’s battery is
disconnected.
8. PROTECTION BY THE ALARM SYSTEM
It is possible to trigger a 10 second alarm cycle by pressing the
B BUTTON
on the remote con-
trol. This alarm cycle can be interrupted by pressing the same button again.
9. PANIC
If needs excluding the alarm system for a time period, it’s possible enable the
SERVICE MODE
modality using its remote control.
To enable the
SERVICE MODE
turn ON the motorcycle’s key and immediately after press hold
the
A BUTTON
of remote control at least 6 sec., the feature enabling is indicated by the LED
fl ashing very fast when the motorcycle’s key is ON.
To disable the
SERVICE MODE
turn ON the motorcycle’s key and immediately after press hold
the
A BUTTON
of remote control at least 6 sec., the feature disabling is indicated by the LED
goes OFF.
10. SERVICE MODE
This product has 2 diff erent timed operation options to protect the vehicle battery (
STOP
MODE
and
DEEP SLEEP MODE
) and an additional system to fast shut off if the battery voltage
level goes down than 10,5V.
11. AUTOMATIC SYSTEMS TO PREVENT
VEHICLE BATTERY DISCHARGE
DEEP SLEEP MODE
(LIMITING CURRENT CONSUMPTION WITH ALARM FUNCTIONS)
It is activated 5 days after the system was armed by remote control or automatically (passive
arming) if no alarms were triggered in this time.
The behavior of this operation option it’s very similar than the
STOP MODE
and the mainly
diff erence it’s the vehicle protection that stay active during the
DEEP SLEEP
phase.
To exit from
DEEP SLEEP MODE
, turn the ignition key ON: the siren will emit a series of
BEEP
sounds. Press the remote control within 20 seconds of the
BEEPS
to disarm the alarm system.
If the remote control is not pressed within 20 seconds, an alarm cycle will be triggered.
STOP MODE
(LIMITING CURRENT CONSUMPTION WITHOUT ALARM FUNCTIONS)
The alarm system automatically switches off in order to limit the consumption of current in
the motorcycle’s battery, automatically excluding the alarm functions but maintaining the
immobilization of the engine: in this condition current consumption is nil.
STOP MODE
is
activated 5 days after the system was armed by remote control or automatically (passive
arming) if no alarms were triggered in this time or if the motorcycle’s battery is almost fl at
(battery voltage level under 10,5V).
To exit from
STOP MODE
, turn the ignition key ON: the siren will emit a series of
BEEP
soun-
ds. Press the remote control within 20 seconds of the
BEEPS
to disarm the alarm system. If the
remote control is not pressed within 20 seconds, an alarm cycle will be triggered.