background image

14

DEFCOM 3.1B 

User Manual

The alarm system is usually supplied with 2 remote controls.
To add or remove remote controls from the memory, gather all the remote controls together 
that are to be included in the alarm system’s memory and proceed as follows:

1.  Disarm the alarm system and turn the ignition key ON for 3 times within 3 sec and keep it 

ON the last time (a BEEP sound confi rms selection)

2.  Turn the ignition key OFF within 10 sec and insert the 

‘OVERRIDE’ CODE

.

3. When the last digit is confi rmed a series of BEEP–BEEP-BOOP-BOOP sounds confi rms the 

code was correct and LED start fl ashing very fast.

4. Within 60 seconds press simultaneously the 2 buttons on the fi rst radio remote control; 

one BEEP sound and the LED turns OFF for 2 seconds to confi rms pairing. Repeat the ope-
ration for all of the other radio remote controls to be paired, each time checking that they 
have been stored successfully (any remote controls that are not paired during this phase 
will be excluded).

5. To complete the pairing phase turn the ignition key ON or wait 60 seconds, a series of 

BEEP–BEEP-BOOP-BOOP sounds confi rms the end of the procedure and the LED turns OFF.

15. ADDITIONAL REMOTE CONTROLS

For this kind of functioning its necessary pair the 

CARD B9.5

 optional, with them is possible 

arming and disarming the alarm system without press the remote control buttons, and Mycro 
remote controls stays operative; after paired the CARD using the 

PRG007 V3 PROGRAMMER

 

to activate the 

CARD B9.5

 press it’s button 5 times.

Alarm system activation in the passive arming mode selected:

It occurs by moving the 

CARD B9.5

 away from the vehicle with the instrument panel OFF, 

after 15 sec. of missing signal from the 

CARD B9.5

 the alarm system arms itself and will be 

signaled as described in paragraph 1.

Alarm system disarming:

It occurs turning ON the instrument panel with 

CARD B9.5

 close to vehicle, disarming will be 

signaled as described in paragraph 1.
If the 

CARD B9.5

 is still close to vehicle at the end of the initial immunity phase all the protec-

tions will be activate only after 15 seconds of missing signal from the 

CARD B9.5

.

USE OF THE CARD B9.5 BUTTON

Alarm system arming: 

when the button is used to arm the system pressing the 

CARD B9.5

 

button all the protections will be included, the alarm system arming immediately and the 
protections will be active after 26 second of immunity time if the 

CARD B9.5

 will not be close 

to vehicle. If the 

CARD B9.5

 is still close to vehicle at the end of the initial immunity phase all 

the protections will be activate only after 15 seconds of missing signal from the 

CARD B9.5

Alarm system disarming:

 when the button is used to disarm 

the system pressing the 

CARD B9.5

 button the disarming will 

be few seconds after pressing the button and the next passive 
arming will be after 50 seconds instead of 15 seconds.

16. KEYLESS MODE BY CARD B9.5

MetaSystem Code:

ABS16900

Summary of Contents for DEFCOM 3.1B

Page 1: ...EN User Manual Manuel Utilisateur FR ...

Page 2: ...e the alarms memory stay available for one minute also after instrument panel activation MEMORISED ALARMS LED SIGNALS Internal movement sensor 1 Flash Contacts 2 Flashes Ignition key sensing 3 Flashes Tampering with cables or battery 4 Flashes The DEFCOM 3 1B alarm provides different signals led siren and flashing of the vehicle indicators according to the different commands received from remote c...

Page 3: ...TON of the remote control briefly the direction indicators flash once the LED switches off if no alarms have been triggered while the alarm system was active If the LED remains ON and the siren also emits a BOOP sound this means that the alarm system was triggered To find out how the alarm was triggered consult the MEMORISED ALARMS ta ble in the chapter 1 NOTIFICATIONS If visual and acoustic signa...

Page 4: ... fast shut off if the battery voltage level goes down than 10 5V 11 AUTOMATIC SYSTEMS TO PREVENT VEHICLE BATTERY DISCHARGE DEEP SLEEP MODE LIMITING CURRENT CONSUMPTION WITH ALARM FUNCTIONS It is activated 5 days after the system was armed by remote control or automatically passive arming if no alarms were triggered in this time The behavior of this operation option it s very similar than the STOP ...

Page 5: ...onnection Active with earth connection Arm Dis switch input using CARD Remote control buttons Button A Arming Disarming Button A Arming Button B Disarming Panic alarm Enabled Disabled Override Code length Only first 3 digits 5 digits Type of low consumption mode Stop Mode Deep Sleep Mode Activation timing of low consumption mode 5 days 10 days Use only the PRG007 PROGRAMMER V3 to select the variou...

Page 6: ...activate it the LED will turn ON turn off and then start to flash after 2 seconds 13 OVERRIDE EMERGENCY CODE DISARM OK x1 x3 x2 x1 x2 ALARM IN ACTIVE PHASE AFTER 26 SEC OVERRIDE EMERGENCY CODE 2 SEC 3 QUICK FLASHES CONFIRM 3 QUICK FLASHES CONFIRM 3 QUICK FLASHES CONFIRM WITHIN 2 SEC WITHIN 10 SEC WITHIN 10 SEC WITHIN 10 SEC WITHIN 10 SEC WARNING if the standard OVERRIDE CODE length 5 digits will b...

Page 7: ...l buttons and Mycro remote controls stays operative after paired the CARD using the PRG007 V3 PROGRAMMER to activate the CARD B9 5 press it s button 5 times Alarm system activation in the passive arming mode selected It occurs by moving the CARD B9 5 away from the vehicle with the instrument panel OFF after 15 sec of missing signal from the CARD B9 5 the alarm system arms itself and will be signal...

Page 8: ...3 92 MHz Frequency of CARD B9 5 2 45 GHz EMERGENCY OVERRIDE CODE to reset immobilizer and alarm functions 17 SPECIFICATIONS Starter motor relay 10A Direction indicator relay 5A 5A Horncontrol Negativeelectronic300mA 18 CAPACTITY OF CONTROLS Initial immunity phase 26 seconds Duration of alarm cycle 26 seconds Interval between alarm cycles 5 seconds Passive arming delay 50 seconds STOP MODE delay 5 ...

Page 9: ...ême après avoir activé le tableau de bord MÉMORIE D ALARME LED Capteur de mouvement 1 Lampeggio Contacts 2 Lampeggi Capteur de clé de démarrage 3 Lampeggi Câble sectionné ou déconnexion de la batterie 4 Lampeggi L alarme DEFCOM 3 1B fournit différents types de signalements led sirène et fonctionnement des feux clignotants du véhicule en fonction des différentes commandes reçues et des différents é...

Page 10: ...TON A de la télécommande les feux clignotants effectueront 1 clignotement et la LED s éteindra si aucune alarme ne s est produite pendant que la centrale est activé Si la LED reste allumée et que la sirène émet aussi un BOOP cela signifie que des alarmes se sont produites pour en connaître l origine consultez le tableau MEMOIRES D ALARMES voir paragraphe 1 SIGNALEMENTS Si pendant l activation ou l...

Page 11: ...me supplémentaire d arrêt rapide en cas de chute de la tension de la batterie en dessous de 10 5 V 11 LES SYSTÈMES AUTOMATIQUES DE PROTECTION DE LA BATTERIE DU VÉHICULE DEEP MODE VEILLE LIMITATION DE LA CONSOMMATION DE COURANT AVEC PROTECTION ACTIVE Il s enclenche 5 jours après l activation par la radiocommande ou l auto activation si aucune alarme n a été détecté pendant ce temps Le fonctionnemen...

Page 12: ...ment Sortie alarm klaxon Continue Alterné Buzzer Arm Dis Activé Désactivé Clignotants Arm Dis Activé Désactivé Control de l alarme Fil Jaune Vert Active si déconnecté de la masse Active si connecté à la masse Control de l alarme Fil Violet Active si déconnecté de la masse Active si connecté à la masse Activation et désactiva tion avec la CARD Boutons de la télécommande Bouton A Activé Désactivé Bo...

Page 13: ...ra puis commencera à clignoter après 2 secondes 13 CODE D URGENCE OVERRIDE DÉSACTIVÉ OK x1 x3 x2 x1 x2 ALARME ACTIVE APRÈS 26 SEC CODE D URGENCE OVERRIDE 2 SEC CONFIRME PAR 3 FLASH RAPIDES CONFIRME PAR 3 FLASH RAPIDES CONFIRME PAR 3 FLASH RAPIDES DANS LES 2 SEC DANS LES 10 SEC DANS LES 10 SEC DANS LES 10 SEC DANS LES 10 SEC ATTENTION Si la longueur standard du CODE OVERRIDE 5 chiffres est modifiée...

Page 14: ...r sur les touches les radiocommandes Mycro fournies restent parfaitement opérationnelles une fois appairée avec l antivol à l aide du pro grammateur PRG007V3 la CARTE B9 5 doit être activée en appuyant sur 5 fois sur le bouton Activation de l antivol avec le mode d activation automatique sélectionné Après éloignement de la CARTE B9 5 du véhicule tableau de bord éteint après environ 15 sec d absenc...

Page 15: ...B9 5 2 45 GHz CODE OVERRIDE pour réinitialiser les fonctions d immobilisation et d alarme 17 SPECIFICATIONS Relais moteur du démarreur 10A Feux clignotants 5A 5A Relais commande Klaxon Négatif électronique 300mA 18 PORTÉE DES COMMANDES Temps de l immunité initiale 26 secondes Durée des cycles d alarmes 26 secondes Intervalle entre les cycles d alarmes 5 secondes Délai d activation automatique 50 s...

Page 16: ...23 Manuel Utilisateur DEFCOM 3 1B ...

Page 17: ...h Radio Equipment Directive 2014 53 EU Frequency Bands in which the radio equipment operates 433 05 MHz 434 79 MHz 10mW e i r p 2402 0 MHz 2480 0 MHz 10mW e i r p Certificate Holder s Address Meta System S p A Via Galimberti 5 42124 Reggio Emilia Italy The full text of the EU Declaration of Conformity is available at the following internet address https docs metasystem it SIMPLIFIED EU DECLARATION...

Reviews: