background image

Subject to change without prior notice.

Metso Flow Control Inc. 

Europe,  Vanha Porvoontie 229, P.O. Box 304, FI-01301 Vantaa, Finland. Tel. +358 20 483 150. Fax +358 20 483 151

North America,  44 Bowditch Drive, P.O. Box 8044, Shrewsbury, M A  01545, USA. Tel. +1 508 852 0200. Fax +1 508 852 8172

South America, Av. Independéncia, 2500-Iporanga, 18087-101, Sorocaba-São Paulo, Brazil. Tel. +55 15 2102 9700. Fax +55 15 2102 9748 

Asia Pacific, 238B Thomson Road, #17-01 Novena Square Tower B, Singapore 307685. Tel. +65 6511 1011. Fax +65 6250 0830

China, 11/F, China Youth Plaza, No.19 North Rd of East 3rd Ring Rd, Chaoyang District, Beijing 100020, China. Tel. +86 10 6566 6600. Fax +86 10 6566 2583

Middle East, Roundabout 8, Unit AB-07, P.O. Box 17175, Jebel Ali Freezone, Dubai, United Arab Emirates. Tel. +971 4 883 6974. Fax +971 4 883 6836

www.metso.com/valves

12 

IMO-215 EN

Summary of Contents for QPX1

Page 1: ...IMO 215 EN 10 2019 QUADRA POWR X Spring Diaphragm Actuators Installation Maintenance and Operating Instructions ...

Page 2: ...ct to change without notice All trademarks are property of their respective owners TABLE OF CONTENTS 1 GENERAL 3 1 1 Warning 3 1 2 Handling QUADRA POWR X Actuators 3 2 INSTALLATION 3 2 1 Operation 4 3 MAINTENANCE 4 3 1 Disassembly 4 3 2 Assembly 5 3 3 Parts lists and Bill of the Materials 6 4 ACCESSORIES 7 4 1 100 Adjustable Stop AS 7 4 2 Mechanical Lockout LD 7 4 3 1 NPT Air Inlet F 7 4 4 Manual ...

Page 3: ...P OF THE ACTUATOR AND THE IDENTIFICATION PLATE IN FEMALE ACTUATORS ARE CORRECTLY INDICATING THE VALVE POSITION FAILURE TO ASSEMBLE THESE PRODUCTS TO INDICATE CORRECT VALVE POSITION COULD RESULT IN DAMAGE OR PERSONAL INJURY THE ACTUATOR MUST BE SIZED ACCURATELY FOR PROPER OPERATION REFER TO INFORMATION ON THE ACTUATOR END OF STROKE TORQUES AND THE APPROPRIATE VALVE BULLETIN FOR OPERATING TORQUES WH...

Page 4: ...2 8 76 103 C 60 4 1 114 155 D 80 5 5 146 198 QPX4 B 40 2 8 153 207 K40 40 mm Keyed M 1 Square C 60 4 1 229 310 D 80 5 5 294 399 QPX5 B 40 2 8 305 414 K40 40 mm Keyed M 1 Square C 60 4 1 458 621 D 80 5 5 587 796 For Direct Control Application QPX2A only available with QPX1 drive type options Under normal operating conditions the actuator requires only periodic observation to ensure proper adjustmen...

Page 5: ... Press driver arm bearings 6 into the body 1 and covers 5 This is best done in an arbor press but a vise could be used if care is taken not to damage the bearing Driver arm bearings are to be pressed in until they are flush or 0 015 in 0 38 mm below the body counterbore or the inside cover surface Press clevis bearings 62 into the clevis 7 2 Apply lubricant MOLYKOTE GN grease on the barrel of shou...

Page 6: ... 2 2 2 2 2 24 Indicator pointer 1 1 1 1 1 26 Washer 16 24 24 32 48 27 Hex head cap screw 8 12 12 16 24 29 Nylon insert lock nut 8 12 12 16 24 30 Spring retainer 1 1 1 1 1 31 y Thrust bearing 2 2 2 2 2 32 Spring housing 1 1 1 1 1 33 Hex head cap screw 4 4 4 4 4 35 Set screw 1 1 1 1 1 37 NTP adapter N A N A 1 1 1 38 Hex head cap screw 4 4 6 10 10 40 Hex Jam Nut 1 1 1 1 1 43 Compression Spring 1 1 1 ...

Page 7: ... in the cover lines up with the hole in the end of the locking plate 5 Secure the locking device with a padlock A padlock with 1 4 5 16 6 35 7 9mm diameter shackle is recommended Removal and storage see Figure 4 1 Remove the padlock and swing the cover out of the way 2 Loosen do not remove the upper jam nut and then remove the locking stud 3 With the locking stud still inserted through the large h...

Page 8: ...etails 2 Stop turning the handle once the desired valve position is achieved 3 When the cause of the malfunction is solved turn the handwheel back to the actuator failsafe position The actuator can now control the valve Maintenance 1 All units are shipped fully greased and require only periodic inspection and greasing If needed use grease fitting 14 to add Molykote type grease until the grease cav...

Page 9: ...e gearbox can then open the valve in case of actuator or supply air failure 9 Mount the gearbox perpendicular to the valve and secure the fasteners 10 Mount the actuator on top of the gearbox Figure 7 Stop screw adjustment 1 Remove the air from the actuator and ensure the valve actuator gear are in the fully closed position 2 With the actuator and gear mounted backout both stop screws on the gear ...

Page 10: ...re using the screw 5 lock washer 6 and hex nut 7 3 Using thread sealant attach the completed fusible plug assembly to the 3 8 NPT port on the QPX diaphragm casing The tubing from the solenoid or positioner will attach to the other end of the pipe nipple Fusible plug Exploded View A A 5 6 7 SECTION A A 1 2 3 4 Figure 9 5 REPAIR KITS SPARE PARTS SERVICE KITS Model Complete Diaphragm QPX1 RKQ 68 RKQ ...

Page 11: ...5 15 mm M Male Square No sign standard version AS 100 Adjustable stop MJX Manual Jackscrew Override SO Fail Open F 1 NPT Air Inlet 2 sign 3 5 only C Model C 2 A B K20 20 mm C D 3 A K35 35 mm B C D 4 B K40 40 mm C D 5 B C D 3 sign Spring Option Details A 1 3 bar 20 psi B 2 8 bar 40 psi C 4 1 bar 60 psi standard D 5 5 bar 80 psi ACCESSORIES Field Mountable Accessories QPX Size 1 2 3 4 5 100 Adjustab...

Page 12: ...0 Iporanga 18087 101 Sorocaba São Paulo Brazil Tel 55 15 2102 9700 Fax 55 15 2102 9748 Asia Pacific 238B Thomson Road 17 01 Novena SquareTower B Singapore 307685 Tel 65 6511 1011 Fax 65 6250 0830 China 11 F China Youth Plaza No 19 North Rd of East 3rd Ring Rd Chaoyang District Beijing 100020 China Tel 86 10 6566 6600 Fax 86 10 6566 2583 Middle East Roundabout 8 Unit AB 07 P O Box 17175 Jebel Ali F...