MC³ 90.10.EX O&M Manual
- 32 -
Name
Description
High Panel Meter
Output Indicating that the Analog Input mapped to the Panel Meter
function has exceeded the limit switch value High Panel Meter. The
settings for this parameter is in the Limit Switches on page 24.
Low Panel Meter
Output Indicating that the Analog Input mapped to the Panel Meter
function has dropped below the limit switch value Low Panel Meter.
The settings for this parameter is in the Limit Switches on page 24.
Ready
All feeders associated with the current recipe are online
AND
There are no fatal communication errors
AND
All feeders are ready (The associated
Ready
output for each feeder is
enabled.)
AND
The Feeder Block logical input is disabled
AND
There are no FAULTS.
Running
The control state of this controller is Running. Setpoint values and Run
Permission bit should be present at all slaves associated with the
selected recipe.
In Control
The
Ready
(same as above) logical output is enabled
AND
Run Permission
logical input is enabled.
Good Feedrate
All feeders associated with the current running recipe are feeding good.
(The associated output for
Feed Good
is enabled in each running
feeder.)
AND
The
In Control
logical output is enabled (same as above).
AND
The feedrate is within the feedrate and deviation limits set in the Limit
Switch Menu.
AND
The recipe is running (the
Running
logical output is enabled).
AND
There are no Warnings or Faults.
In Menu System
Output indicating that the user interface is not in one of its main screens
In Calibration
NOT USED
Register Access
Used by the controller to permit the user to enter the low level register
editor.
Screen Locked
NOT USED
Serial Setpoint
The controller is using serial communications to derive the setpoint.
Analog Setpoint
The setpoint method is set to Analog or Ratio.
COM1 Comm Lost
Output indicating that Scalenet serial communication has been initiated,
and later timed out.
DF1 Comm Lost
Output indicating that DF1 serial communication has timed out.
Power Fail
Power was removed from the controller. This output only turns on when
the controller is initialized during a power up sequence.
Used Fdr Fault
One of the slave controllers used by the selected recipe has a Fault
condition.
Free Fdr Fault
One of the slave controllers
not
used by the selected recipe has a Fault
Condition.
Used Fdr Lost
One of the slave controllers used by the selected recipe is no longer
communicating on the serial port or has been taken offline.
Free Fdr Lost
One of the slave controllers
not
used by the selected recipe is no longer
communicating on the serial port or has been taken offline.
Used Fdr Warn
One of the slave controllers used by the selected recipe has a Warning
condition.
Free Fdr Warn
One of the slave controllers
not
used by the selected recipe has a
Warning Condition.