Merloni Elettrodomestici
DISHWASHER EVO3
Service manual
EN
03-05-20/0
36-54
Language Issue/Edition
Page
Dispenser connection
rinse aid and detergent dispenser
Fan / heating element connection
the fan and the heating element have the same relay actuation; the heating
element is activated when the pressure switch is in full and the fan when the
pressure switch is in empty
LINE
NEUTRAL
Q1
TRIAC
DIRECTIONAL CONTROL VALVE
(Detergent / rinse aid dispensers)
LINE
NEUTRAL
FAN
LS1A
RELAY SPDT HE
FAN 1
PRESSURE SWITCH
OPEN
FULL
2000W 230V
CONCEALED / OPEN