Merlino RED-RL Series User Manual Download Page 3

WARRANTY - ATTENDANCE - MATERIAL SUPPLIED AS STANDARD

3

1)

2)

3)

4)

5)

MERLINO elettronica s.a.s. di Meroni N.
Via Como, 33/A - 20851 Lissone - MB
E-mail: [email protected]
Web-site: www.merlinoelettronica.it

The warranty

ATTENDANCE

MATERIAL SUPPLIED AS STANDARD

is valid for a period of 12 months from the consignment date and expires at the

end of this period, irrespective of whether the appliance has in fact been used. The guarantee
covers all parts of the device if the materials or assembly of said parts are shown to be faulty and
in respect of the following conditions:

The warranty covers replacement of all those parts shown to be of faulty manufacture
under normal conditions of use.
The warranty is not valid unless accompanied by a copy of the invoice proving purchase.
The warranty is not valid in the following cases:

a - if the device has been tampered with in any way;
b - use of the device in ways not conforming to the instructions and warnings

given in this manual;

c - damage caused by an unsuitable working environment or phenomena not

dependent on normal operation (e.g. an unsuitable mains voltage and/or
frequency values);

d - repairs carried out by persons or technical assistance centres not authorised

by the manufacturer.

The resulting costs and risks associated with transport, packing and labour are the
responsibility of the purchaser.

The replacement of the device and/or extension of the period of guarantee validity
following a fault are excluded.

Compensation will not be paid for damages occurring as a result of the device being
inoperative while repairs are carried out.

Where not explicitly specified, reference should be made to 85/374/EEC on the
responsibility for faulty products as incorporated in Italian Decree D.P.R. 224 of 1998.

The servicing, meant like informative support of answer to any type of relating clarification the
device in object, and the repairs are supplied directly from the manufacturer.

The "RED-RL" optoelectronic active laser light curtain, consists of the following elements sup-
plied suitably packed:

- Transmitter (TX) complete with M12 - 5 pole output connector with 5 m long cable
- Receiver

(RX) complete with M12 - 8 pole output connector with 5 m long cable

- Copy of the present manual including the “

DECLARATION OF CONFORMITY”

- Cylindrical Test Piece to verify the integrity of the declared detection capability

Pag. 3

DESIGN AND MANUFACTURE
OF ELECTRONIC EQUIPMENT

MERLINO elettronica s.a.s. di Meroni N.
Via Como, 33/A - 20851 Lissone - MB
E-mail: [email protected]
Web-site: www.merlinoelettronica.it

MISU-RED-RL-UK-1.0

Summary of Contents for RED-RL Series

Page 1: ...IC PROTECTIVE DEVICE AOPD AT LASER EMISSION PREFACE This manual provides the user and or installer with the information required for correct use of the RED RL device in the application for which it wa...

Page 2: ...15 PAG 16 TX RX 1 Preface 2 Contents 3 Warranty Attendance Supplied material 4 Legend Verifying the protected area 5 Introduction Installation 6 Chosen of the Device Precautions 7 Available functions...

Page 3: ...istance centres not authorised by the manufacturer The resulting costs and risks associated with transport packing and labour are the responsibility of the purchaser The replacement of the device and...

Page 4: ...covered by this manual mitter section of the RED RL light guard emitting LASER radiation with a wavelength of eceiver section of the RED RL light guard acting as a sensor and command and control devi...

Page 5: ...TX and Receiver RX are perfectly parallel and fixed using the supplied means at the working distance specified when ordering and reported on the rating plate under the heading Working Distance Keep th...

Page 6: ...sensor units are correctly fixed using special supports in electrically insulating material Connection of other equipment to the power source used to power the RED RL device is not recommended This co...

Page 7: ...o the inside EDM circuit Between this conductor and ground 0V of power supply has to be in series connected the normally open switches of the external output load devices thus from being able to test...

Page 8: ...power on RED4 RL model only D LEDs STATUS CASE BLINKING ON OFF BLK ALT RUN OFF MUTE E F G H OFF OFF ON BLK ALT RUN OFF MUTE OFF ON OFF BLK ALT RUN OFF MUTE OFF OFF ON BLK ALT RUN BLINKING MUTE BLINKI...

Page 9: ...hite Green Yellow Brown Marrone SW1 SW2 BLANKING R F EDM STR RSTR 5 Grigio 6 Rosa 7 Blu 8 Rosso Grey Pink Blue Red SW1 SW2 24V GND Connect Shield to GND Collegare lo Schermo a GND If the functions E D...

Page 10: ...point for vertically installed light curtains with a detection capability of no more than 40 mm are given below is the safe distance to be respected when installing the device is a constant establish...

Page 11: ...ON 5 METERS CABLE LENGHT M12 CONNECTOR TX 5 POLE RX 8 POLE HOUSING ANODIZED ALUMINIUM CROSS SECTION 53 x 103 mm AVAILABLE FUNCTIONS E D M XTERNAL EVICE ONITOR START RESTART INTERLOCK BLANKING PROTECTE...

Page 12: ...SW2 MUTE2 SW2 24V GND GND RED2 RL 1 2 3 5 4 Male plug Female socket Female socket Male plug If the function TEST is not used short circuit the conductors 4 5 and connect them to the 0V of power supply...

Page 13: ...to reach the safety caegory declared 7 8 BLUE RED SHIELD ELECTRICAL CONNECTIONS RX 12 1 MUTING MERLINO elettronica s a s di Meroni N Via Como 33 A 20851 Lissone MB E mail merlinoelettronica tiscali it...

Page 14: ...merlinoelettronica tiscali it Web site www merlinoelettronica it 167 56 56 53 53 30 51 30 50 66 30 20 167 51 50 66 20 50 4 x M5 45 4 x M5 45 50 Pag 14 DESIGN AND MANUFACTURE OF ELECTRONIC EQUIPMENT M...

Page 15: ...at with the machine stationary and power to the laser guard on no obstacle in the protected area the green indicator is lit with the machine stationary and power to the on in the presence of an obsta...