The Transmitter and Receiver units do not require particular maintenance. However, the frontal
heads of the two sections protective of the optics, with the holes for exit and entrance of the laser
light beam, should be cleaned daily to remove large quantities of dust.
Avoid rubbing the screens with abrasive cloths as rubbing causes static electricity and attracts
dust. To clean, use alcohol. Avoid plastic solvents.
When the device is used for the first time, to guarantee safe conditions, the correct setting of the
functions must be controlled. When using the device for the first time, operation of the device in
the particular application must first be verified. This must be done by specialist personnel. Acci-
dent prevention legislation specifies that this control should be performed daily.
Before beginning any form of work, it is good practice to verify that:
with the machine stationary and power to the laser guard on (no obstacle in the protected
area), the green
indicator is lit.
with the machine stationary and power to the
on in the presence of an obsta
cle in the protected area, the red
indicator is lit.
moving parts are not accessible to personnel. Any extraordinary maintenance must
therefore be carried out under the strict supervision of the safety manager. All accesses
not pro tected by electro sensitive protective devices must be equipped with fixed material
barriers or other.
A sheet indicating the daily checks must be compiled by the operator of the machine and must
be clearly visible near the workstation.
DAILY CONTROLS AND PERIODICAL TESTS
RUN
ALT
laser guard
with the machine running, introduction of the test piece at any point in the protected area
switches the green indicator to the red
indicator, shutting down the machine within the
specified time.
The "RED-RL" active optoelectronic visible light laser emission intangible guard consists of the
following elements, provided on request as spare parts:
M12 - 5 poles output connector for TX with 5 m long cable...................
M12 - 8 poles output connector for RX with 5 m long cable................
Manual with duplicate of the “
DECLARATION OF CONFORMITY
ALT
MATERIAL SUPPLIED AS SPARE PARTS
a)
b)
d)
c)
-
...... CON-M12-5P-5M
-
......... CON-M12-8P-5M
-
”........... MISU-RED
- Cylinder for testing the integrity of the detection capability ........................... TEST-PIECE
Description
Code
MISU-RED-RL-UK-1.0