EDR4 1169 G 10/03
11
insulation with the staples. Cut the wire to the length needed and strip approxi-
mately 10 mm of the insulation. Connect the wire to the two terminals on the
pushbutton. Mount the pushbutton to the wall.
CAUTION Keep the push button cable at least 600 mm clear of mains power ca-
bles if it is parallel to them. Do not run the push button wiring through the same
cavities in the wall as the mains power. Mains and low voltage wiring can cross
with no problems.
STEP 18: We recommend that you allow the antenna wire at the rear of the opener to
hang freely behind the opener. Generally the remote control transmitter will
be received from a longer distance if the antenna is visible.
STEP 19: Remove or disable any door locking mechanism. Failure to disable the locking
may result in damage to the opener or door.
STEP 20: Fit the light bulb and light cover into position and lock the cover securely with
its latch.
STEP 21: Manually raise the door until the trolley passes over the torpedo and engages. If
the trolley will not reach the torpedo then you must follow the appropriate proce-
dure in the next section on setting door travel limits.
STEP 22: Attach the red release rope through the hole in the trolley release lever.
Ensure the release cord is threaded through the manual release warning card.
Setting the door travel limits
limits
NOTE Repeated operation of the opener in a short period of time during setup may
trigger the thermal cutout of the motor. In this
case you will have to wait for approximately
five minutes for the motor to cool sufficiently
to continue the installation process. If the unit
has overheated you will hear the relays click-
ing in response to the transmitter or pushbutton
but the motor will not operate. After cooling
down, normal operation is able to resume.
The limit adjustment screws are inside the lamp
cover and are marked as up limit and down limit.
One full turn of either screw results in around 250mm
of trolley travel.
STEP 1:
Plug the opener into an earthed three-pin 220-240V outlet and switch on the power. The
opener’s courtesy lamp may turn on, or may flash for five seconds.
STEP 2:
Remove the lamp cover by turning the catch on its underside. Remove the green control
panel cover to expose the setup controls. Observe the red and green indicator LEDs. The red LED
will stay on continuously at the fully closed position. The green LED will stay on continuously at the
fully open position. Identify the green operate button.
Ensure the door is engaged on the trolley.
Door travel limit
adjustments inside.
Remove lamp cover.