background image

8

NOTE: This accessory must be used for all
installations where timer-to-close is enabled.

After the opener has been installed and adjusted, the
Protector System™ accessory can be installed.
Instructions are included with this accessory.

The Protector System™ provides an additional
measure of safety against a small child or animal
being trapped under a

door. It uses an infra-red

beam, which when broken by an obstruction, causes a
closing door to open and prevents an open door from
closing

and

is

strongly

recommended

for

applications where young children may be
present.

Setting Timer-To-Close (optional)

NOTE: The Protector System

TM

MUST be installed

to enable this feature.

The timer-to-close feature will automatically close the
door after the preset time. The time can be adjusted up
to 180 seconds using the trim pot located on the
control board. timer-to-close can be disabled by
adjusting the trim pot to 0s.

Installing and adjusting:

• Turn the opener off

• Install the Protector System

TM

using the brackets,

wires and instructions provided with the product.
Twist the two white (only) wires together and
terminate them into the white (2) terminal. Twist the
two white/black wires together and terminate them
into the grey (3) terminal.

• Ensure the trim pot on the opener is set to 0s.

• Turn the opener on

• Allow 5 minutes for the beams to self-learn to the

unit, (do not walk through the beam during this time).

• Ensure the door is in the closed position, then adjust

the trim pot to the desired closing time.

0s

180s

50s

Quick-Connect Terminals

C. To insert or release

wire, push in tab with
screwdriver tip

A. Strip wire

(11 mm)

B. Twist like coloured

wires together

Red

Grey White

7/16" (11 mm)

Red LED
MUST BE ON

Red LED
MUST BE ON

IR Beam

IR Beam

IR Beams must be installed

to detect a 100mm high

obstacle at any point along

the floor.

14

SAFETY FIRST!

Whilst Chamberlain have engineered safety features into your door opener, we urge you to consider fitting IR
Beams to your new door opener. In many countries these devices are compulsory to assist in preventing serious
injury or property damage. For your own peace of mind and the safety of others please install this inexpensive
safety device.

Door may operate unexpectedly, therefore do not allow anything to stay in the path of the door.

INSTALL THE PROTECTOR SYSTEM™ (IR BEAMS) OPTIONAL ACCESSORY

Timer-To-Close is NOT recommended for
applications where young children may
be present.

Do not adjust the trim pot whilst the door is
in the open position.

Door will activate when the trim pot is
adjusted in the open position

Summary of Contents for MRC950

Page 1: ...ercial Rolling Door Opener Installation and Operating Instructions Owners Copy Please keep these instructions for future reference This manual contains IMPORTANT SAFETY information DO NOT PROCEED WITH...

Page 2: ...IMPORTANT Chain reduction assemblies that may interfere with the safe and proper operation of the MRC950 must be removed All hand chains must be removed prior to fitting the MRC950...

Page 3: ...for a binding or sticking door Sticking binding or unbalanced doors must be repaired before installing this opener Do not wear rings watches or loose clothing while installing or servicing a door ope...

Page 4: ...3 Ensure that there is at least 45mm from the edge of the curtain to the edge of the bracket If the roller door drum is on the edge of the curtain or is a smaller diameter additional clearance may be...

Page 5: ...ft to the door bracket is tightly secured INSTALLING THE STOP COLLAR 5 3 SAFETY CHECK Is the stop collar installed YES proceed to the next step NO install the stop collar before proceeding Release cab...

Page 6: ...wn firmly opener will make a clicking noise Disable all locks and remove any ropes connected to the door Take care when operating the manual release as an open door may fall rapidly due to weak or bro...

Page 7: ...oor mounting bracket to the wall If the door bracket needs to be relocated due to opener width refer section 3 preferred clamping method Clamp the opener on the door axle and door bracket in the marke...

Page 8: ...ioned approximately halfway or at least 2m from the open position the opener is engaged and the power is turned on Press and hold the LMT Limit button until the orange indicator LED starts flashing an...

Page 9: ...ed out the safety reverse system test outlined above install the warning labels provided with your opener as shown The risk of entrapment label must be installed adjacent to the release handle at a he...

Page 10: ...gether and terminate them into the grey 3 terminal Ensure the trim pot on the opener is set to 0s Turn the opener on Allow 5 minutes for the beams to self learn to the unit do not walk through the bea...

Page 11: ...d be pre programmed by the factory If adding a new wall control program into the opener before mounting the unit as detailed in section 16 professional LRN Press LRN or LED will FLASH TO ADD Transmitt...

Page 12: ...choice on the keypad 2 then press and hold the ENTER button 3 Release the button when the opener courtesy LEDs flash once 3 the code is learned Alternate programming method using the motion detecting...

Page 13: ...all instructions included with the CM475 unit to test for proper operation and testing of the SPU SPECIAL FEATURES OPTIONAL ACCESSORIES 1 Solenoid roller door lock SRDLK01 2 24VDC power output for ex...

Page 14: ...1 001B6451 3S 041A6778 2 041D6637 041B0029 19 SPARE PARTS 041A6811 1 Mount plate sub assembly including motor 041B0029 Sungear kit Aluminium 041B0603 Front upper housing 041A6814 1 Base housing 041D6...

Page 15: ...system 7 Model C379 Wireless finger print access system 8 Model C98 Motion detecting control panel 9 Model 760 Outside keyswitch 10 Model CM1702 Outside quick release 11 Model C77 The Protector Syste...

Page 16: ...or flashing Realign receiving eye sensor clean lens and secure brackets Symptom The RPM Sensor Short travel 150 200mm 6 8 Unplug unit to reset Try to operate opener check diagnostic code If it is sti...

Page 17: ...inding call a trained door systems technician Clear any ice or snow from the floor area where the door closes Repeat the limit and force setting in section 10 11 Repeat safety reverse test after adjus...

Page 18: ...light turns off automatically after 2 1 2 minutes MAINTENANCE OF YOUR OPENER Once a Month Manually operate door If it is unbalanced or binding call for professional door service Check to be sure door...

Page 19: ...d are warranted for the remaining portion of the original warranty period This Chamberlain Limited Warranty provides benefits which are in addition to your other rights and remedies as a consumer Excl...

Page 20: ...114A4200F 2011 The Chamberlain Group Inc TM Trademark of The Chamberlain Group Inc Registered Trademark of The Chamberlain Group Inc...

Reviews: