25
EARTH GROUND ROD INSTALLATION (OPTIONAL)
NOTE:
For proper operation, do not connect the earth
ground rod to the green screw on the outlet plate.
Install earth ground rod within 900 mm of the operator.
Disconnect and remove the green/yellow ground wire connected to the screw
terminal of the control board.
Attach earth ground rod wire to the screw terminal of the control board marked
. Ensure the power wiring ground connection remains securely connected to
the green screw on the outlet plate.
FUSE
OPEN
Z1
FUSE
OPEN
R4
GATE 2
ACCESSORY
POWER
MAGLOCK
ALARM
GATE 1
J4
D15
C2
MOV2
C2
R4
24 VAC/
SOLAR
INPUT
J4
Ground Screw
Control Box
12 Gauge Wire
Earth Ground
Installation (Optional)
3' (0.9 m)
8' (2.4 m)
WIRING
» EARTH GROUND ROD INSTALLATION (OPTIONAL)
1
2
3
POWER
C64
BATT 1
BATT 2
C2
U2
BATT 1
MOV2
24 VAC/
INPUT
J4
USE DEDICATED CIRCUIT
CONNECT POWER
The batteries are the main source of power for the operator. The operator is a
battery run system. Both batteries are charged in circuit using the transformer
(provided). The 24 Vac input can accept a charging transformer (26 Vac, 29 VA or
36 Vdc, 40 VA).
Connect the plugs from the batteries to the connectors on the control board.
Connect Mains Power to the charging transformer.
BATT 2
Connector
BATT 1
Connector
1
1
2