19
NOTE
If an obstruction is detected when opening, the M2 leaf will always close fully
before the M1 leaf.
motor leaf delay trimmer (+ DEL -)
NOTE
Press RESET after adjusting the trimmer.
Turn this clockwise to increase the time delay that occurs between the start of movement
of the M1 leaf and the start of movement of the M2 leaf. This is essential when using gate
tabs or overlapping leaves. To prevent clashing of the gate leaves, increase the motor leaf
delay.
•
Full clockwise: maximum time delay of 30 seconds between M1 and M2 moving
•
Full anti-clockwise: minimum time delay of 3 seconds
•
Other positions: adjust for delay times of between 3 and 30 seconds
enable lock strike delay jumper (STRIKE)
If the ELU module is connected, along with an electric lock, then this jumper may be required.
When the STRIKE jumper is connected across its two pins, then an open command to a
fully closed gate will be delayed by 1 second to allow time for a solenoid lock to release.
enable testing of safety devices jumper (TEST)
Connecting the TEST jumper across its two pins will cause the controller to verify the
operation of the photocell and / or safety edge before every operation. This test switches
off the power to the safety device and verifies that the device’s output changes state.
Therefore the safety device must be capable of being tested in this way. A 200 ms delay
is created before every movement. The TEST jumper must be removed if safety devices
are not fitted.
Summary of Contents for G915D
Page 23: ...23...