background image

 

403321001_001 2016-08-31 

 

   

5. 

PRECAUTIONS: 
Caution:  

Removing screws and opening of this device may invalidate the warranty.

 

Caution: 

”. 

Caution:

 

It is important to read these instructions for use and these precautions prior to device operation. 

Caution:  

Replace fuses only with the same type and rating: 5 x 20 mm 3.15A/250V(2 each).

 

Caution:  

Do not sterilize the MetaSTAR RF Generator. Sterilization may damage the unit. 

Caution:

 

Reconditioning, refurbishing, repair, modification, of the device to enable further use is expressly 
prohibited as it may result in loss of function and/or patient injury. 

Caution:  

Do not block or restrict the openings on the bottom and back of the MetaSTAR RF Generator, as they 
provide the required airflow for cooling. 

Caution:  

If  electromagnetic  interference  with  other  equipment  is  suspected,  reorient  the  device  or  remove 
possible sources of interference (e.g., cellular phones, radios, etc.) from the room. 

Caution:  

Any monitoring electrodes recommended to be placed as far as possible from the SpineSTAR Ablation 
Instrument when high frequency surgical equipment and physiological monitoring equipment are used 
simultaneously on the same patient. Monitoring systems incorporating high frequency current-limiting 
devices are recommended for use.  

Caution:  

Needle monitoring electrodes are not recommended. 

Caution:  

Patient  should  not  come  into  contact  with  earthed  metal  parts,  the  use  of  antistatic  sheeting  is 
recommended. 

Caution:  

Cables to the surgical electrodes are recommended to be positioned such that contact with patient or 
other leads is avoided. 

 

Caution:

  

Do not continue to deliver RF for more than 30 seconds if the impedance bar is more than 75% filled 
and temperature is not increasing. 

 

The lightning flash with arrowhead symbol, within an equilateral triangle, is intended to alert the 
user to the presence of un-insulated "dangerous voltage" within the products enclosure that may 
be of sufficient magnitude to constitute a risk of electric shock to persons. 

 

The symbol with an open book with the letter “i” is intended to alert the user to the presence of 
important operating and maintenance (servicing) instructions in the literature accompanying the 
unit. 

 

The  symbol  with  a  person  reading  an  open  book  is  intended  to  alert  the  user  to  read  and 
understand the operator’s manual prior to use. Failure to follow instructions could result in death 
or serious injury. 

6. 

ENVIRONMENTAL PROTECTION: 

Follow local governing ordinances and hospital practice regarding the disposal of the SpineSTAR Ablation Instrument 
(see SpineSTAR Ablation Instrument IFU)  

7. 

HOW SUPPLIED: 

The MetaSTAR RF Generator is supplied in a semi-ready-to-use state. The units’ box contains the MetaSTAR RF 
Generator, and a detached power cord. All other devices are available separately. 

7.1. 

Accessories: 

7.1.1. 

Hand Switch Cable 

7.1.2. 

AE Cable 

7.2. 

Single Use Devices 

– See below for other devices required for Tumor Ablation. 

SpineSTAR Ablation Instrument* 

* Applied Part, V

PPMax

: Same as 

Output

. See Appendix A, I. Specifications. 

 

 

Summary of Contents for MetaSTAR 3195

Page 1: ...West Merit Parkway South Jordan Utah 84095 U S A 1 801 253 1600 U S A Customer Service 1 800 356 3748 Authorized Representative Merit Medical Ireland Ltd Parkmore Business Park West Galway Ireland 31...

Page 2: ...PPLIED 4 7 1 Accessories 4 7 2 Single Use Devices See table below for other devices required for Tumor Ablation 4 8 INSTRUCTIONS FOR USE 5 8 1 Set Up Error Bookmark not defined 8 2 MetaSTAR RF Generat...

Page 3: ...FU for the applicable device s used during the procedure Warning Hazardous electrical output This equipment is for use only by qualified medical personnel trained in the use of the MetaSTAR RF Generat...

Page 4: ...istatic sheeting is recommended Caution Cables to the surgical electrodes are recommended to be positioned such that contact with patient or other leads is avoided Caution Do not continue to deliver R...

Page 5: ...SpineSTAR Ablation Instrument Hand Switch Cable andAE Cable are available as backup prior to use 8 3 MetaSTAR RF Generator Nomenclature Symbols ON power Type BF Applied Part Volume Control OFF power W...

Page 6: ...LOW LED 4 RF ON BLUE LED 5 POWER ON GREEN LED 6 Soft Key Button 1 7 Soft Key Button 2 8 Soft Key Button 3 9 Soft Key Button 4 10 Hand Switch Cable Socket 11 AE Cable Socket 12 Fuse Drawer 13 ON OFF Ma...

Page 7: ...be connected to the AE Cable socket on the MetaSTAR RF Generator using the AE Cable inspect the AE Cable for damage If the SpineSTAR Ablation Instrument is connected properly Distal and Proximal tempe...

Page 8: ...TAR Ablation Instrument is properly placed 1 Both thermocouple temperatures are displayed in amber 30 C Note temperatures are displayed in blue when temperature is 30 C 2 Electrode is extended to the...

Page 9: ...instructions for use and maintenance instructions The sole obligation of MERIT under this warranty shall be limited to the replacement of the MetaSTAR RF Generator or equivalent models at no charge t...

Page 10: ...erit Medical Systems Inc 1600 West Merit Parkway South Jordan Utah 84095 U S A 1 801 253 1600 U S A Customer Service 1 800 356 3748 Authorized Representative Merit Medical Ireland Ltd Parkmore Busines...

Page 11: ...operation Enclosure IP 21 III Operating Conditions Temperature 59 F to 104 F 15 C to 40 C Relative Humidity 30 to 75 non condensing Atmospheric Pressure 878 to 1082cmH2O 86 to 106kPa Whenever the tem...

Page 12: ...Instrument are intended for use in the electromagnetic environment specified below The customer or the user of the System should assure that it is used in such an environment Immunity test IEC 60601...

Page 13: ...ntific and Medical ISM RF Equipment MDD 93 42 EEC Medical Device Directive Council Directive Concerning Medical Devices APPENDIX E COMPATIBLE POWER CORDS Continental Europe 2 0m 10A Inter Power PN 862...

Page 14: ...in a particular installation If this equipment does cause harmful interference to other devices which can be determined by turning the equipment off and on the user is encouraged to try to correct the...

Page 15: ...e 39 F Watchdog Fault Turn Power off Turn Power back on If error persists contact MERIT Customer Service 41 53 W RAM Power On Self Test Turn Power off Turn Power back on If error persists contact MERI...

Reviews: