Mercury SR-10K User Manual Download Page 3

Doc. 10107-0007  Rev 1.04

Page 3

Mercury Security Corporation, 

©

 2005

SR-10K

Description

The SR-10K is a complete stand-alone access controller, using either magnetic-stripe
cards or cipher (keypad) codes for identifying valid users.
The Card Reader with Keypad and the Interface Module are the SR-10K system's
major components. Separating the door control and other interface connections not
only simplifies the installation, but it greatly improves security by placing the door strike
relay inside the protected area.
The SR-10K offers unparalleled versatiltiy in its class. The investment an installer makes
in learning the SR-10K is greatly rewaded by the number of different applications that
can be solved by the SR-10K.
And cerainly not least, unlike other strictly stand-alone access controllers, the SR-10K
supports expansion to multiple readers at a site.

Programming

A Master Card places the SR-10K into programming mode. Commands are entered via
the keypad on the SR-10K reader.  In some cases the entry of user cards may also be
required.  A buzzer and two bicolor LEDs provide immediate feedback to the operator.

Card Database Options

The SR-10K supports three different card database modes:
1 -

RANDOM 

mode, supports 

up to 100 users

 (factory default):

This mode allows the use of any magnetic stripe card with standard 'track-2' encod-
ing, such as the 'MS-SR10CC25', pre-encoded packs of 25 cards, or cards from
many other access systems, or even bank cards.
Cards are added into 'user slots' by reading the card at the time of enrollment.
Individual or a block of 'user slots' may be deactivated.

2 -

BLOCK

 mode, supports 

up to 1,600 users

:

This database mode requires that all cards are encoded as a set. (Block orders are
typically shipped within a week of the order). Add-on orders can specify an existing
block number and a continuation point. The activation and deactivation of block
cards may be done without the cards and may be performed either individually or in
blocks.

3 - '

FACILITY CODE

' mode, there is 

no limit to the number of users

 supported,

since the SR-10K is not checking for a unique code:
This mode is useful for low security applications where access cards are already in
use.  The number of leading card digits to check is configured from zero to 9 digits.
Setting the number of card digits to check to 'none'  causes the SR-10K to accept
any magnetic stripe card as a valid user- also known as the ATM Mode, used to
accept 'any bank card'.
An additional setting allows the SR-10K to skip up to 15 card digits before assem-
bling the facility code. This feature is used in case the facility code does not start at
the beginning of the card.

OVERVIEW

Summary of Contents for SR-10K

Page 1: ...Doc 10107 0007 Rev 1 04 Page 1 Mercury Security Corporation 2005 SR 10K SR 10K Mag Stripe Access System Users Guide...

Page 2: ...ode 6 Two Door Access Control 14 Mode 7 Access Control with Door Bell Feature 15 Mode 8 Dual Output Toggle on Valid Access 15 Installation 16 Maintenance 17 Specifications 17 Dimensions and Typical Co...

Page 3: ...p to 100 users factory default This mode allows the use of any magnetic stripe card with standard track 2 encod ing such as the MS SR10CC25 pre encoded packs of 25 cards or cards from many other acces...

Page 4: ...isplay the status of an exter nal device connected to an input such as an alarm panel s armed disarmed indicator An Operating Mode is a collection of these functions intended for a specific applicatio...

Page 5: ...etermines the installation wiring details and User Level assignment Lost Master Card Follow the steps outlined below to set a new Master Card in case the current Master Card is lost remove power from...

Page 6: ...on Command 12 Delete a card using the card 1 2 select Command 12 user card read the card to be deleted from that slot Command 13 Delete a range of cards 1 3 select Command 13 0 9 0 9 select the first...

Page 7: ...mmand 22 1 3 select the user level 1 3 0 1 0 9 0 9 0 9 enter the first user slot to activate 0000 through 1599 0 1 0 9 0 9 0 9 enter the last user slot to activate 0000 through 1599 Command 23 Delete...

Page 8: ...s to indicate transfer in progress The transfer of the entire block mode card database 1 600 users may take up to 1 minute The completion of a succesful transfer is indicated with the long beep A tran...

Page 9: ...with the Block Database Mode 4 The Block Number Command 94 must be set for Block Database Mode operation 5 In Facility Code Database Mode the digit count specifies the the number of card digits to rea...

Page 10: ...rd read will pulse Output K1 no effect if the door is unlocked A upward read will toggle the state of Output K1 locking or unlocking the door Configuration Inputassignments Input I1 is connected to a...

Page 11: ...the status of Input I2 User Level 2 and 3 A downward read will pulse Output K1 no effect if the door is unlocked A upward read will toggle the state of Output K1 locking or unlocking the door Configur...

Page 12: ...rd pulses Output K2 allowing the momentary closure to simulate a key switch input to an alarm panel User Level Specifications User Level 1 Both downward and upward read will pulse Output K1 User Level...

Page 13: ...etosimulate a key switch input to an alarm panel User Level Specifications UserLevel1 CardshavingthisUserLevelarerejectedifthecontactonInputI2isopen IfthecontactonInput I2 is closed Both downward and...

Page 14: ...t to Output K2 and functions as the access control input User Level 1 users are valid only when a closed contact is presented to this input UpperLEDassignment The upper LED follows Input I2 displaying...

Page 15: ...th Door Buzzer Control Description This mode is intended for applications where the outputs need to be toggled instead of the standard momentary pulse operation Both outputs are toggled Level 1 users...

Page 16: ...l off moisture for outdoor mounting To avoid having ESD electrostatic discharge interfering with the operation of the reader the reader casing shall be grounded This can be accomplished be tying the m...

Page 17: ...g nominal Interface Dimension 3 25 83mm W x 2 9 74mm L x 1 4 36mm H Weight 4 oz 120 g nominal Environmental Temperature 55 to 85 degrees C storage 40 to 75 degrees C operating Humidity Reader 100 RHN...

Page 18: ...ss over cable Maximum distance between reader and interface is 500 feet using 22AWG wires 6 COND STRAIGHT Typical Wiring Configuration Communication Wiring Maximum total cable length 4 000 ft 1 200 m...

Page 19: ...nap track The new module dimension is 4 25 x 2 75 inches Connection to the card reader is also changed from modular jack to a screw terminals for more convenient termination GND BLK BZR ORG LED BRN CL...

Reviews: