Mercury MTTR01 User Manual Download Page 3

 

MTTR01 User Manual 

 

Remove the connection between the testing leads and the circuit being 
tested, and turn the meter power off before opening the meter case. 

 

The internal circuit of the meter shall not be altered at will to avoid 
damage of the meter and any accident. 

 

A soft cloth and mild detergent should be used to clean the surface of 

the tester on a regular basis. No abrasive and solvent should be used 
to prevent the surface of the tester from corrosion or damage. 

 

The tester is suitable for indoor use only. 

 

Turn the tester power off when it is not in use and take out the battery 
when not using for a long time. Check the battery regularly; replace the 

battery immediately if any signs of leaking appear. Battery acid will 
damage the tester.  

 

General Specifications 

 

Max display:  

 

LCD (6000 count) 64 x 43mm 

Polarity:    

 

Automatic, indicated minus, assumed plus 

Measure method:    

double integral A/D switch implement 

Sampling speed:    

2.5 times per second 

Over-load indication:  

“OL” is displayed  

Operating temperature:  

0ºC to 40ºC, at <75%RH  

Storage temperature:  

-30ºC to 60ºC, at <85%RH 

Power:   

 

9Vdc (1 x PP3 battery supplied) 

Low battery indication:  

“ ” 

Display resolution:   

6000 counts 

Resistance: 

 

600Ω to 60MΩ 

Capacitance: 

 

40nF - 4000µF 

Frequency: 

 

9.99Hz - 9.99MHz 

Test temperature:   

-20°C - 1000°C 

Duty cycle: 

 

5% to 95% 

Dimensions:  

 

188 x 81 x 48mm   

Weight:    

 

420g (including battery) 

 

 
 

Summary of Contents for MTTR01

Page 1: ...Item ref 600 104UK MTTR01 TRUE RMS DIGITAL MULTITESTER WITH USB INTERFACE User Manual...

Page 2: ...The rotary switch should be in the right position and no changeover of range shall be made while measurement is conducted to prevent damage When the tester is working at an effective voltage over 60V...

Page 3: ...ake out the battery when not using for a long time Check the battery regularly replace the battery immediately if any signs of leaking appear Battery acid will damage the tester General Specifications...

Page 4: ...MTTR01 User Manual Layout...

Page 5: ...tch for selecting different measuring ranges and also serves as an ON OFF switch To preserve battery life please ensure the range switch is turn to OFF position when not in use 7 10A Probe socket sock...

Page 6: ...ched off 13 Strong magnet that allows meter to be attached to any iron steel surface in case both hands are required to take the measurement 14 Mini USB socket at the bottom of the unit to connect to...

Page 7: ...is selected use Select button to choose between resistance measuring diode testing and continuity testing 7 Relative mode is selected use Rel USB button to select between auto range mode and relative...

Page 8: ...e current or resistance The length of the bar is proportionate to the 0 5999 digital count above it The bar graph has a sampling rate 10 times higher of the digital number display this make it ideal f...

Page 9: ...nd 600V Frequency Range 40Hz 400Hz Overload Protection 600Vrms Reading True rms Max Input voltage 750Vac rms DC Current RANGE RESOLUTION ACCURACY Remark 600uA 0 1uA 1 0 of rdg 7D Auto range 6000uA 1uA...

Page 10: ...10 sec and use no more than once every 15 min Frequency Range 40Hz 400Hz Reading True rms Resistance RANGE RESOLUTION ACCURACY Remark 600 0 1 1 0 of rdg 5D Auto range 6K 1 0 8 of rdg 5D 60k 10 600k 1...

Page 11: ...ad protect 600Vdc ac rms Transistor Range Resolution Test condition hFE 1 Vce 2 2V Ib 4uA Over load protect 600Vdc ac rms Temperature RANGE Scope RESOLUTION ACCURACY C 20 to 0 C 0 1 C 6 0 of rdg 5 C 0...

Page 12: ...to device or circuit being measured 4 Turn on power of the device or circuit being measured The voltage value will appear on the digital display along with the voltage polarity Please note In small r...

Page 13: ...ddition 10A function is designed for intermittent use only RESISTANCE MEASUREMENT 1 Connect red lead to II C F V HzhFE and black lead to COM 2 Set the range switch to three functions are available by...

Page 14: ...t until is displayed on the screen 3 Connect the red test lead to the anode of the diode to be measured and black test lead to cathode 4 The meter will show the approximate forward voltage of the diod...

Page 15: ...the approximate hFE value TEMPERATURE MEASUREMENT 1 Using the K type thermocouple connect red lead to II C F V HzhFE and black lead to COM 2 Set the Range switch to C F 3 Attach the end of the thermo...

Page 16: ...e and enter relative mode with displayed on the screen and reading display with 0 2 Now any measurement taking the unit will only display the difference between the reference value and the current rea...

Page 17: ...MTTR01 User Manual Software http cdn avslgroup com downloads 600104_MTTR01 software zip...

Page 18: ...MTTR01 User Manual Setting BATTERY AND FUSE REPLACEMENT...

Page 19: ...ery into the case top Tidy the battery leads so that they will not be pinched by the battery cover 4 The meter is protected by fuses mA F0 5A 600V Fast blow Breaking capacity is 20KA dimensions are 38...

Page 20: ...ssed as Electrical or Electronic equipment and should not be disposed with other household or commercial waste at the end of its useful life The goods must be disposed of according to your local counc...

Reviews: